Finish Thompson
UCR/UCP ANSI sealless pumps, AK/AV/VKC/MSVKC vertical mag-drive, and DB Series drum pumps — real specs and chemical compatibility, as stocked and specified by LibertyCES.
Finish Thompson makes sealless chemical pumps: UCR (pure ETFE containment) and UCP (ETFE-lined ductile iron) ANSI drop-in models, AK/AV/VKC/MSVKC vertical mag-drive pumps for sump and tank service, and DB Series drum pumps in polypropylene or PVDF. Its FTI Air and Filter Pump divisions add AODD pumps and filtration systems.
What LibertyCES specifies from Finish Thompson

ANSI drop-in compatible sealless pumps — pure ETFE containment (UCR) or ETFE-lined ductile iron (UCP). 8 of 10 harsh-chemical-service failures trace to seal failure or misapplied materials; sealless removes that failure point.

Vertical sealless mag-drive for sump, tank, and pit service. Titanium and Hastelloy C available as a premium wetted tier for oxidizer service.
Under the Finish Thompson umbrella
Air-operated double diaphragm pumps, FT025 through FT30P. The FT30P is a 3-inch polypropylene AODD pump rated to 300 gpm and 120 psi max air supply, with bolted construction and a stall-resistant air valve that eliminates separate pilot valves — designed for aggressive chemical transfer, not general utility duty.
MTD and related filtration pump systems, independently confirmed for acid transfer service. Dedicated page and catalog PDF in progress.
A Transfer Point Is a Containment Point
Bolted construction with precision-molded liquid chambers, a stall-resistant air valve that eliminates separate pilot valves, and fewer parts overall — fewer wear points on an aggressive chemical, and fewer places for a leak to start. Polypropylene is the body; the diaphragm and seat material is where the actual chemical-compatibility specification happens, and the temperature limit follows the selected elastomer, not a single blanket rating.

Finish Thompson — Real Catalog Spec Data
| Product Line | Model | Category | Material | Size / Capacity | Temp Rating |
|---|---|---|---|---|---|
| DB Series | DB3 | Pump | Polypropylene or PVDF | 20 ft head / 15 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB4 | Pump | Polypropylene or PVDF | 29 ft head / 18 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB5 | Pump | Polypropylene or PVDF | 35 ft head / 19 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB5.5 | Pump | Polypropylene or PVDF | 31 ft head / 30 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB6 | Pump | Polypropylene or PVDF | 33 ft head / 40 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB6H | Pump | Polypropylene or PVDF | 54 ft head / 42 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB7 | Pump | Polypropylene or PVDF | 34 ft head / 69 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB8 | Pump | Polypropylene or PVDF | 45 ft head / 61 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB9 | Pump | Polypropylene or PVDF | 67 ft head / 46 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB10 | Pump | Polypropylene or PVDF | 51 ft head / 96 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB11 | Pump | Polypropylene or PVDF | 74 ft head / 116 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB15 | Pump | Polypropylene or PVDF | 98 ft head / 136 gpm (60Hz) | PP 180F / PVDF 220F |
| DB Series | DB22 | Pump | Polypropylene or PVDF | 201 ft head / 221 gpm (60Hz) | PP 180F / PVDF 220F |
| SP Series | SP10 | Pump | Polypropylene or PVDF | 63 ft head / 55 gpm (60Hz); self-priming, lifts 25ft | PP 180F / PVDF 220F |
| SP Series | SP11 | Pump | Polypropylene or PVDF | 68 ft head / 104 gpm (60Hz); self-priming, lifts 25ft | PP 180F / PVDF 220F |
Sourced from Finish Thompson's own catalog documentation.
FT30P: Finish Thompson's 3-inch polypropylene diaphragm pump
The FT30P is the largest pump in Finish Thompson's FTI Air non-metallic AODD line, launched March 2026: 300 gpm at 120 psi inlet air, 0.5-inch solids, polypropylene wetted parts, about 140 lb, and a stainless-steel air valve with no separate pilot valve. FTI Air backs it with a five-year warranty.
Pair it with Finish Thompson mag-drive and drum pumps on the same chemical package, and size it with our free diaphragm pump sizing calculator.

MSDB: run-dry tolerance and flooded suction, same pump
The MSDB is Finish Thompson's multistage sealless mag-drive for high-head, low-flow chemical service — up to about 306 ft (MSDB3, 60 Hz). With a carbon bushing it tolerates occasional dry running, but it is not self-priming, so suction design still decides pump life.
Our six-page checklist covers the bushing limits, the 2 ft NPSH margin and every suction-piping rule from the manual.
Size it right before you buy

The Finish Thompson MSDB pump-review checklist: carbon-bushing run-dry limits, NPSH margin and the suction-piping rules that decide pump life.

Enter flow, head, SG and plant air. See the air pressure and SCFM your duty needs on a real FTI Air FT30P curve, then get the worksheet by email.
Frequently Asked Questions
What is the difference between Finish Thompson UCR and UCP pumps?
UCR uses pure ETFE containment, is ANSI drop-in compatible, and handles up to ~250°F. UCP uses ETFE-lined ductile iron with optimized hydraulics and a snap-fit impeller for simplified service, rated to ~180°F.
Are FTI Air and Filter Pump the same company as Finish Thompson?
Yes — both are independently-branded divisions of Finish Thompson, each with their own product catalog and identity, covering AODD pumps (FTI Air) and filtration systems (Filter Pump) respectively.
What chemicals are Finish Thompson sealless pumps rated for?
Sodium hypochlorite is confirmed across both the UCR/UCP horizontal line and the AK/AV/VKC/MSVKC vertical line. PFA, PTFE, and ETFE liners are confirmed for phosphoric and nitric acid service.
What are the specs on the Finish Thompson FT30P AODD pump?
The FT30P is a 3-inch air-operated double-diaphragm pump with polypropylene wetted parts, rated to 300 gpm maximum flow, 120 psi maximum air supply, and 0.5-inch maximum particle size. Operating temperature is determined by the selected diaphragm material rather than a single blanket rating — eight diaphragm materials are available (Neoprene, Santoprene, FKM, EPDM, PTFE, Buna, Hytrel, and polyurethane), with polypropylene or PVDF seats.
Which Finish Thompson pump fits your chemistry and duty?
Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].
Finish Thompson models in the LibertyCES catalog
111 models across 26 product lines. For most models that state them (the middle 80%): flow 1–1,500 gpm (230–329,300 L/h); connection sizes 0.75–48 in; pressure to 100 psi (6.9 bar); temperature to 250°F (121°C). Extremes are in the table.
| Model / line | Type | Size / capacity / flow | Pressure | Temperature | Wetted material | Source |
|---|---|---|---|---|---|---|
| DB Series DB3 | Pump | 15 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB4 | Pump | 18 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB5 | Pump | 19 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB5.5 | Pump | 30 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB6 | Pump | 40 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB6H | Pump | 42 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB7 | Pump | 69 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB8 | Pump | 61 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB9 | Pump | 46 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB10 | Pump | 96 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB11 | Pump | 116 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB15 | Pump | 136 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| DB Series DB22 | Pump | 221 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| SP Series SP10 | Pump | 55 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| SP Series SP11 | Pump | 104 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| SP Series SP15 | Pump | 120 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| SP Series SP22 | Pump | 253 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| MSDB Series MSDB 2 | Pump | 69.8 gpm | to 180 °F (to 82 °C) | Polypropylene/PPS or PVDF/PPS | Finish Thompson — Sealless Plastic Pumps | |
| MSDB Series MSDB 3 | Pump | 69.3 gpm | to 180 °F (to 82 °C) | Polypropylene/PPS or PVDF/PPS | Finish Thompson — Sealless Plastic Pumps | |
| KC/MSKC Series MSKC | Pump | 60 gpm | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealless Plastic Pumps | |
| Accessory VFD (Variable Frequency Drive) | Accessory | sized by motor HP/kW and supply voltage | n/a | Finish Thompson — Sealless Plastic Pumps | ||
| Accessory Power Monitor (Process Defender) | Controller | 50/60Hz, up to 690VAC, 4 protection levels (run-dry/dead-head/excess power/de-coupling/priming loss) | n/a | Finish Thompson — Sealless Plastic Pumps | ||
| Accessory Baseplate | Accessory | fits DB/SP/MSDB/UC Series | epoxy-painted steel, fiberglass, or polymer concrete | Finish Thompson — Sealless Plastic Pumps | ||
| Accessory Pedestal Assembly | Accessory | fits NEMA 56C (or 145TC-256TC/IEC 90-160 for UC Series) | n/a | Finish Thompson — Sealless Plastic Pumps | ||
| UCR Series UCR326 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR326H | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR328 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR436 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR436L | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR438 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR1516 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR1516L | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR1518 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR1518L | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR2110 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR2110L | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR3110 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR3156 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR3158 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR3210 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR4310H | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCR Series UCR6410 | Pump | 1–1450 gpm | to 250 °F (to 121 °C) | Ductile iron with ETFE lining/barrier | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP326 | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP326H | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP436L | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP1516 | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP1516L | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP1518 | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP1518L | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UCP Series UCP3156 | Pump | 450 gpm | to 180 °F (to 82 °C) | Polypropylene barrier w/ carbon-fiber shell | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | |
| UC Legacy Series UC326 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC326H | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC328 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC436 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC436L | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC438 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC1516 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC1516L | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC1518 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC1518L | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC2110 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC2110L | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC3110 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC3120 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC3156 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC3158 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC3210 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC4310H | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| UC Legacy Series UC6410 | Pump | to 250 °F (to 121 °C) | Ductile iron with ETFE lining (predecessor to UCR) | Finish Thompson — ANSI Sealless Pumps / ULTRAChem Line | ||
| EF Series EFV/EFP/EFS | Drum Pump | 17 gpm | PP 150F/PVDF 160F/316SS 212F | PP, PVDF, or 316SS | Finish Thompson — Drum/Barrel Pumps | |
| PF Series PFV/PFP/PFS/PFM | Drum Pump | 40 gpm | PP 160F/PVDF 120F/316SS 220F | PP, PVDF, or 316SS | Finish Thompson — Drum/Barrel Pumps | |
| SF Series SFVV/SFV/SFS/SFP/SFM | Drum Pump | 37 gpm | PP/PP-PVDF 175F/PVDF 140F/316SS 212F | PP, pure PVDF, pure PP/PVDF, or 316SS | Finish Thompson — Drum/Barrel Pumps | |
| TT Series TTS/TTC/STTS | Drum Pump | 16 gpm | to 150 °F (to 66 °C) | 316SS or CPVC | Finish Thompson — Drum/Barrel Pumps | |
| TB Series TBS | Drum Pump | 20 gpm | to 150 °F (to 66 °C) | 316SS | Finish Thompson — Drum/Barrel Pumps | |
| HVDP Series HVDP-HR | Drum Pump | progressive cavity, up to 20000 cP | to 180 °F (to 82 °C) | 316SS | Finish Thompson — Drum/Barrel Pumps | |
| HVDP Series HVDP-LR | Drum Pump | progressive cavity, up to 100000 cP | to 180 °F (to 82 °C) | 316SS | Finish Thompson — Drum/Barrel Pumps | |
| BT Series BTS | Drum Pump | 10 gpm | to 200 °F (to 93 °C) | 316SS | Finish Thompson — Drum/Barrel Pumps | |
| TM Series TMS | Drum Mixer | 14 gpm | to 200 °F (to 93 °C) | 316SS | Finish Thompson — Drum/Barrel Pumps | |
| AC Series AC4 | Pump | 321 gpm | 100 psi (6.9 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC5 | Pump | 321 gpm | 100 psi (6.9 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC5H | Pump | 321 gpm | 100 psi (6.9 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC5R | Pump | 321 gpm | 100 psi (6.9 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC6 | Pump | 321 gpm | 100 psi (6.9 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC6H | Pump | 321 gpm | 100 psi (6.9 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC8 | Pump | 321 gpm | 120 psi (8.3 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| AC Series AC8H | Pump | 321 gpm | 120 psi (8.3 bar) | to 300 °F (to 149 °C) | 316 Stainless Steel | Finish Thompson — Sealed Pumps |
| GP Series GP11 | Pump | 126.4 gpm | 15 psi (1 bar) | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealed Pumps |
| GP Series GP22 | Pump | 200.9 gpm | 15 psi (1 bar) | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealed Pumps |
| GP Series GP32 | Pump | 200.9 gpm | 15 psi (1 bar) | to 180 °F (to 82 °C) | Polypropylene or PVDF | Finish Thompson — Sealed Pumps |
| AK Series AK4 | Pump | 124 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AK Series AK5 | Pump | 124 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AK Series AK5R | Pump | 124 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV4 | Pump | 321 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV5 | Pump | 321 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV5H | Pump | 321 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV5R | Pump | 321 gpm | to 100 °F (to 38 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV6 | Pump | 321 gpm | to 150 °F (to 66 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV6H | Pump | 321 gpm | to 150 °F (to 66 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV8 | Pump | 321 gpm | to 150 °F (to 66 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| AV Series AV8H | Pump | 321 gpm | to 150 °F (to 66 °C) | 316 Stainless Steel | Finish Thompson — Vertical Pumps | |
| VKC Series VKC5.5 | Pump | 0.5–69 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| VKC Series VKC6 | Pump | 0.5–69 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| VKC Series VKC6H | Pump | 0.5–69 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| VKC Series VKC7 | Pump | 0.5–69 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| VKC Series VKC8 | Pump | 0.5–69 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| VKC Series VKC10 | Pump | 0.5–69 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| MSVKC Series MSVKC | Pump | 0.5–61 gpm | 60 psi (4.1 bar) | to 140 °F (to 60 °C) | Polypropylene or PVDF | Finish Thompson — Vertical Pumps |
| Flow Meter 211013/211013-1/211013-2/211013-3/211013-4/211013-5/A101529 | Accessory | 5–32 gpm | 32–120 °F (0–49 °C) | PP, PVDF, or 316SS | Manufacturer documentation on file | |
| Nozzle (squeeze-lever) 111030 series (32 part numbers) | Accessory | for EF/PF/TB/TT/SF series, 3/4in or 1in barb, standard or long-spout | PP, PVDF, Aluminum, or 304SS; wetted: FKM/EPDM/FFKM/FDA Buna/PTFE | Manufacturer documentation on file | ||
| Nozzle (auto shut-off) 107231/107232 | Accessory | wetted parts SS & FKM, for PFS/TBS/SFS/EFS | 304 Stainless Steel | Manufacturer documentation on file | ||
| Discharge Tubing various (16 part numbers) | Hose | 3/4-1.5in, 5-8ft standard or custom by-the-foot, for EF/PF/TB/TT/SF/BT/HVDP series | -22–175 °F (-30–79 °C) | Reinforced PVC, PVC, EPDM, FDA Nitrile/Buna-N, UHMWPE, or Conductive PE | Manufacturer documentation on file |
This table is part of the equipment catalog dataset (CSV and JSON).
Send James your spec
Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.
Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated