Named chemicals

Methanol
Direct answer

LibertyCES has documented Strainer in Solvents/Organics service, including Methanol. Wetted materials to confirm: stainless steel wire mesh. Documented models include Fil-Trek 98 Series automatic strainer. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

98 Series explicitly notes a -50F rating for methanol service application.

Materials documented for this service

  • stainless steel wire mesh

Products cited for this service

Fil-Trek 98 Series automatic strainer

Real Specifications

SpecValueSource document
98 Series methanol service rating-50°F rated for miscella filtration & separation (methanol) serviceFil-Trek — Industrial Filtration
98 Series constructionMotorized, continuously self-cleaning wedge-wire basket strainer with automatic blowdown on a differential-pressure setpoint; carbon steel, 304SS, or 316SSFil-Trek — Industrial Filtration
Control tiersL1 standard NEMA 4 (Siemens PLC/HMI); L2 any voltage/PLC, NEMA 4 or 4X; L3 hazardous area (NEMA 7 or Pressure+Purge panel)Fil-Trek — Industrial Filtration
Install / Failure Note

Methanol service in a classified (hazardous) area requires the L3 control tier (NEMA 7 or Pressure+Purge panel) rather than the standard L1 NEMA 4 panel — pairing a standard control tier with a classified-area methanol line is a real misspecification risk.

Cold methanol service isn't just a material-compatibility question — a strainer without an adequate low-temperature rating in a -50°F miscella line fails before it ever clogs. Fil-Trek's 98 Series only earns its cold-service claim because it's explicitly rated for it, and pairing that with the correct electrical classification tier is where a generic strainer selection usually goes wrong.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can Strainer handle Solvents/Organics?

98 Series explicitly notes a -50F rating for methanol service application.

What wetted materials should Strainer use in Solvents/Organics service?

Materials documented for this service: stainless steel wire mesh. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Solvents/Organics chemicals does this cover?

Named chemicals in this documentation: Methanol.

Which Strainer models are documented for Solvents/Organics?

Documented examples include Fil-Trek 98 Series automatic strainer.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.

Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated