UV Disinfection System for General Manufacturing / Industrial Process Water
30+ years spec experience. Send James the process data and get a real answer — not a catalog page.
Request a Spec Review →What LibertyCES's vendor documentation shows
The case study's design logic is why this cell exists: UV handles microbial risk post-softening without adding a second chemical loop. AXEON's captured line is the catalog match — Sterilume-EX / Sterilume-HO lamps rated up to 9,000 hours, stainless chambers, Safety-Loc connectors (power disconnect before lamp removal), optional real-time UV intensity sensors, and optional solenoid integration that stops flow if UV output drops below a safe threshold. Also explicitly protects against chlorine-resistant Cryptosporidium and Giardia.
Products cited in this application
Real Specifications
| AXEON SHF (industrial) flow rate | up to 290 GPM | axeon-water-filtration-ion-exchange-disinfection-injection.md |
| AXEON PRO50 (light commercial) flow rate | 10-30 GPM, with LightWise technology | axeon-water-filtration-ion-exchange-disinfection-injection.md |
| Lamp life rating | Sterilume-EX / Sterilume-HO lamps rated up to 9,000 hours | axeon-water-filtration-ion-exchange-disinfection-injection.md |
| Safety interlock | Safety-Loc connectors disconnect power before lamp removal; optional solenoid valve stops flow if UV output drops below a safe threshold | axeon-water-filtration-ion-exchange-disinfection-injection.md |
Without the optional solenoid interlock, a failing UV lamp keeps passing flow with no automatic response. The solenoid option converts UV disinfection from a monitored process into an interlocked one that shuts flow rather than silently under-dosing water below the safe threshold.
The case study's own logic is that UV handles microbial risk after softening without a second chemical loop — but that only holds if the system carries real-time intensity monitoring and the flow-interlock solenoid, since an un-monitored UV system can fail dark with nobody knowing until a water-quality test catches it.
Every claim on this page traces to real, vendor-published documentation on file with LibertyCES. Confirm current specifications with the manufacturer before final specification.
Related Guides
FAQ
Is UV Disinfection System used in General Manufacturing / Industrial Process Water?
The case study's design logic is why this cell exists: UV handles microbial risk post-softening without adding a second chemical loop. AXEON's captured line is the catalog match — Sterilume-EX / Sterilume-HO lamps rated up to 9,000 hours, stainless chambers, Safety-Loc connectors (power disconnect before lamp removal), optional real-time UV intensity sensors, and optional solenoid integration that stops flow if UV output drops below a safe threshold. Also explicitly protects against chlorine-resistant Cryptosporidium and Giardia. This is strong evidence.
What products are specified for UV Disinfection System in General Manufacturing / Industrial Process Water?
Documented examples include AXEON SHF (industrial, up to 290 GPM), AXEON K+ (commercial, 45-80 GPM, advanced controls), AXEON PRO50 (10-30 GPM, LightWise technology reducing energy use and quartz sleeve fouling), AXEON VH410 (5-18 GPM, high-output lamps), AXEON S2Q-PA (1-3.5 GPM) — confirm current specifications with the manufacturer before final selection.
Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].