UV Disinfection System for General Manufacturing / Industrial Process Water

Strong evidence

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

What LibertyCES's vendor documentation shows

The case study's design logic is why this cell exists: UV handles microbial risk post-softening without adding a second chemical loop. AXEON's captured line is the catalog match — Sterilume-EX / Sterilume-HO lamps rated up to 9,000 hours, stainless chambers, Safety-Loc connectors (power disconnect before lamp removal), optional real-time UV intensity sensors, and optional solenoid integration that stops flow if UV output drops below a safe threshold. Also explicitly protects against chlorine-resistant Cryptosporidium and Giardia.

Products cited in this application

AXEON SHF (industrial, up to 290 GPM)AXEON K+ (commercial, 45-80 GPM, advanced controls)AXEON PRO50 (10-30 GPM, LightWise technology reducing energy use and quartz sleeve fouling)AXEON VH410 (5-18 GPM, high-output lamps)AXEON S2Q-PA (1-3.5 GPM)

Real Specifications

AXEON SHF (industrial) flow rateup to 290 GPMaxeon-water-filtration-ion-exchange-disinfection-injection.md
AXEON PRO50 (light commercial) flow rate10-30 GPM, with LightWise technologyaxeon-water-filtration-ion-exchange-disinfection-injection.md
Lamp life ratingSterilume-EX / Sterilume-HO lamps rated up to 9,000 hoursaxeon-water-filtration-ion-exchange-disinfection-injection.md
Safety interlockSafety-Loc connectors disconnect power before lamp removal; optional solenoid valve stops flow if UV output drops below a safe thresholdaxeon-water-filtration-ion-exchange-disinfection-injection.md
Install / Failure Note

Without the optional solenoid interlock, a failing UV lamp keeps passing flow with no automatic response. The solenoid option converts UV disinfection from a monitored process into an interlocked one that shuts flow rather than silently under-dosing water below the safe threshold.

The case study's own logic is that UV handles microbial risk after softening without a second chemical loop — but that only holds if the system carries real-time intensity monitoring and the flow-interlock solenoid, since an un-monitored UV system can fail dark with nobody knowing until a water-quality test catches it.

Every claim on this page traces to real, vendor-published documentation on file with LibertyCES. Confirm current specifications with the manufacturer before final specification.

Related Guides

Chlorine Dioxide Generator Selection Guide →

FAQ

Is UV Disinfection System used in General Manufacturing / Industrial Process Water?

The case study's design logic is why this cell exists: UV handles microbial risk post-softening without adding a second chemical loop. AXEON's captured line is the catalog match — Sterilume-EX / Sterilume-HO lamps rated up to 9,000 hours, stainless chambers, Safety-Loc connectors (power disconnect before lamp removal), optional real-time UV intensity sensors, and optional solenoid integration that stops flow if UV output drops below a safe threshold. Also explicitly protects against chlorine-resistant Cryptosporidium and Giardia. This is strong evidence.

What products are specified for UV Disinfection System in General Manufacturing / Industrial Process Water?

Documented examples include AXEON SHF (industrial, up to 290 GPM), AXEON K+ (commercial, 45-80 GPM, advanced controls), AXEON PRO50 (10-30 GPM, LightWise technology reducing energy use and quartz sleeve fouling), AXEON VH410 (5-18 GPM, high-output lamps), AXEON S2Q-PA (1-3.5 GPM) — confirm current specifications with the manufacturer before final selection.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].