High Performance Butterfly Valve for Data Centers

Strong evidence

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

What LibertyCES's vendor documentation shows

Explicitly categorized for data centers by AVCO. The 60" Class 150 ceiling is the largest size from this vendor — campus-scale chilled-water headers rather than rack-level cooling. Double offset disc gives bi-directional bubble-tight shut-off, the real requirement for isolating a cooling loop without draining it.

Products cited in this application

AVCO BFV HP (lug-type double offset disc; Class 150: 2"-60", Class 300: 2"-36"; 316SS or carbon steel body, 304SS/316SS disc, 17-4PH stem, TFE or RTFE seats; API 609 Type B, API 598, ASME B16.5, ASME B16.47; vendor categories Data Center, Food & Beverage, Power, Refining)

Real Specifications

BFV HP size & pressureClass 150: 2"-60"; Class 300: 2"-36"avco-valve-chemical-processing.md
BFV HP construction316SS or Carbon Steel body, 304SS/316SS disc, 17-4PH stem, TFE or RTFE seats; double offset disc designavco-valve-chemical-processing.md
BFV HP certificationsAPI 609 Type B, API 598, ASME B16.5, ASME B16.47avco-valve-chemical-processing.md
60" at Class 150 is the largest size AVCO publishes — that's campus-scale chilled-water header territory, not rack-level cooling, and the double offset disc's bi-directional bubble-tight shut-off is what lets a data center isolate one cooling loop without draining the whole header.

Every claim on this page traces to real, vendor-published documentation on file with LibertyCES. Confirm current specifications with the manufacturer before final specification.

Related Guides

Industrial Actuation & Severe Service Valves →Industrial Valves, Actuators & SCADA Systems →Knife Gate vs Ball vs Butterfly Valve — Abrasive Slurry Isolation →

FAQ

Is High Performance Butterfly Valve used in Data Centers?

Explicitly categorized for data centers by AVCO. The 60" Class 150 ceiling is the largest size from this vendor — campus-scale chilled-water headers rather than rack-level cooling. Double offset disc gives bi-directional bubble-tight shut-off, the real requirement for isolating a cooling loop without draining it. This is strong evidence.

What products are specified for High Performance Butterfly Valve in Data Centers?

Documented examples include AVCO BFV HP (lug-type double offset disc; Class 150: 2"-60", Class 300: 2"-36"; 316SS or carbon steel body, 304SS/316SS disc, 17-4PH stem, TFE or RTFE seats; API 609 Type B, API 598, ASME B16.5, ASME B16.47; vendor categories Data Center, Food & Beverage, Power, Refining) — confirm current specifications with the manufacturer before final selection.