Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Sector Application

Double Containment Piping for Direct Lithium Extraction (DLE)

Strong evidence

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

What LibertyCES's vendor documentation shows

Duo-Pro is Asahi's own recommended system for DLE brine/acid handling per the ASAHI FOR DLE source; named chemistries are sodium hypochlorite, chlorine dioxide and acids (lithium-rich brine eluents). The 30-day EPA containment figure is the quotable design basis on a DLE permitting conversation.

Products cited in this application

Asahi/America Duo-Pro double containment in PP, PVDF or ECTFE (1x3 through 16x20, 150psi + drainage ratings, outer pipe designed to meet the EPA standard of at least 30 days of containment, simultaneous or staggered butt fusion, leak-detection cable installable on 2x6 and larger)Asahi/America PAL-AT cable-based leak detectionLiquidWatch II electronic leak detection

Real Specifications

Duo-Pro size/pressure range1x3 through 16x20, 150 psi + drainage ratingsasahi-america.md
Outer pipe containment standardDesigned to meet the EPA standard of at least 30 days of containmentasahi-america.md
Leak detection cable install thresholdPAL-AT cable-based leak detection installable on 2x6 and largerasahi-america.md
Recommended DLE valve/actuator pairingType-14 Diaphragm Valve + Series 19 MAV MultiPack electric actuator, 75% duty cycle, NEMA 4X enclosureasahi-america.md
Duo-Pro materialsPP, PVDF, or ECTFEasahi-america.md
Install / Failure Note

Type-14's top-entry design isolates the bonnet from the fluid, so only the body and diaphragm (available in PVDF/PTFE/EPDM) ever touch the brine — the failure mode it's built to avoid is abrasive-slurry or corrosive-brine intrusion into the actuator side of the valve.

A DLE brine line runs acid and abrasive slurry continuously for the life of the plant — Duo-Pro's 30-day EPA containment design basis on the outer pipe is a real, vendor-published number worth quoting in a permitting conversation, not a rounded-up estimate.

Every claim on this page traces to real, vendor-published documentation on file with LibertyCES. Confirm current specifications with the manufacturer before final specification.

Related Guides

Direct Lithium Extraction Piping & Valve Infrastructure →Double Containment Is More Than Two Pipes →Industrial Process Piping Systems & Engineered Fabrication →

FAQ

Is Double Containment Piping used in Direct Lithium Extraction (DLE)?

Duo-Pro is Asahi's own recommended system for DLE brine/acid handling per the ASAHI FOR DLE source; named chemistries are sodium hypochlorite, chlorine dioxide and acids (lithium-rich brine eluents). The 30-day EPA containment figure is the quotable design basis on a DLE permitting conversation. This is strong evidence.

What products are specified for Double Containment Piping in Direct Lithium Extraction (DLE)?

Documented examples include Asahi/America Duo-Pro double containment in PP, PVDF or ECTFE (1x3 through 16x20, 150psi + drainage ratings, outer pipe designed to meet the EPA standard of at least 30 days of containment, simultaneous or staggered butt fusion, leak-detection cable installable on 2x6 and larger), Asahi/America PAL-AT cable-based leak detection, LiquidWatch II electronic leak detection — confirm current specifications with the manufacturer before final selection.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].