Named chemicals

Sulfuric Acid (93%)Hydrochloric AcidHydrofluosilicic Acid
Direct answer

LibertyCES has documented Pipe in Acids service, including Sulfuric Acid, Hydrochloric Acid and Hydrofluosilicic Acid. Wetted materials to confirm: Advanced PE and ECTFE/Halar. Documented models include Netafim FlexNet HP. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

26 real named installed-project case list with field concentrations, several exceeding general resistance tables (93% sulfuric acid seen twice).

Materials documented for this service

  • Advanced PE (NSF/ANSI/CAN 61-G)
  • ECTFE/Halar (chosen over Advanced PE for H2SO4 in one RO plant)

Products cited for this service

Asahi Advanced PE / Chem Proline / Ultra ProlineNetafim FlexNet HP (heap leach)

Real Specifications

SpecValueSource document
Sulfuric acid resistance ceiling (general table)Resistant up to 85% concentration, PVC/FKM valve pairingAsahi/America — Advanced PE Industrial Piping Systems (Chem Proline / Chem Prolok / Poly-Flo)
93% sulfuric acid real field installsAnomatic OH (2013, replaced CPVC) and Chemco CA (2013, replaced PVC) both ran 93% H2SO4 in Chem Proline, above the general table's stated 85% ceilingAsahi/America — Advanced PE Industrial Piping Systems (Chem Proline / Chem Prolok / Poly-Flo)
Hydrochloric acid resistanceResistant to 37% HCl, PVC/FKM valve pairing, Vented Ball Valves required for off-gas reliefAsahi/America — Advanced PE Industrial Piping Systems (Chem Proline / Chem Prolok / Poly-Flo)
Hydrofluosilicic acid resistanceResistant up to 50% concentration (fluoridation dosing), PVC/EPDM valve pairingAsahi/America — Advanced PE Industrial Piping Systems (Chem Proline / Chem Prolok / Poly-Flo)
ALD70 valve diaphragm sulfuric acid limit38°C max — far below the pipe's 85%-concentration ratingNetafim Mining — Heap Leaching Products Catalog
Install / Failure Note

Two of Asahi's 26 documented Advanced PE installations ran 93% sulfuric acid — Anomatic OH and Chemco CA, both 2013, both replacing failed CPVC or PVC — above the general resistance table's own stated 85% ceiling; a real field data point to flag to engineering before quoting, not an automatic green light past 85%.

Acid service piping fails at whichever component has the lowest real ceiling, not the pipe body — Netafim's own ALD70 valve diaphragm caps sulfuric acid at 38°C while Advanced PE pipe carries it to 85% concentration at operating temperature, exactly the kind of mismatch a category-level "acid-resistant piping" quote misses.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can Pipe handle Acids?

26 real named installed-project case list with field concentrations, several exceeding general resistance tables (93% sulfuric acid seen twice).

What wetted materials should Pipe use in Acids service?

Materials documented for this service: Advanced PE (NSF/ANSI/CAN 61-G), ECTFE/Halar (chosen over Advanced PE for H2SO4 in one RO plant). Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Acids chemicals does this cover?

Named chemicals in this documentation: Sulfuric Acid (93%), Hydrochloric Acid, Hydrofluosilicic Acid.

Which Pipe models are documented for Acids?

Documented examples include Asahi Advanced PE / Chem Proline / Ultra Proline, Netafim FlexNet HP (heap leach).

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].