Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Chemical Compatibility

Level Instrument — Oxidizers/Disinfectants

Moderate evidence

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

Named chemicals

Hydrogen Peroxide (off-gassing)Sodium Hypochlorite (off-gassing)

What LibertyCES's vendor documentation shows

Radar/guided-wave technology explicitly noted as not affected by vapor/outgassing relevant to H2O2/NaOCl off-gassing.

Materials documented for this service

  • Radar (non-contact, unaffected by outgassing)

Products cited for this service

Icon MLR-70GF Signet 2260/2291

Real Specifications

Icon radar level sensors — vapor/outgassing toleranceExplicitly rated 'not affected by vapor/outgassing'icon-process-controls-level-sensors.md
ProScan 3 frequency/range80GHz, 10m standard / 20m optionalicon-process-controls-level-sensors.md
ProScan 3 antenna/enclosure materialPP antenna; CPVC or 316SS enclosureicon-process-controls-level-sensors.md
ProScan 2 antenna materialPTFE Teflon® or 316SSicon-process-controls-level-sensors.md
MLR-70 probe material / ratingFEP Teflon-coated probe, IP67icon-process-controls-level-sensors.md
Hydrogen peroxide and sodium hypochlorite off-gas in the tank headspace, which is exactly the condition that defeats older ultrasonic level sensors relying on a clean acoustic echo. Icon's radar line is explicitly rated as unaffected by vapor and outgassing, which is the real reason to specify radar over ultrasonic for tanks holding these two oxidizers — not a general 'radar is more advanced' claim.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Is Level Instrument compatible with Oxidizers/Disinfectants?

Radar/guided-wave technology explicitly noted as not affected by vapor/outgassing relevant to H2O2/NaOCl off-gassing. This is moderate evidence.

What materials are documented for Level Instrument in Oxidizers/Disinfectants service?

Materials documented for this service: Radar (non-contact, unaffected by outgassing). Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm with a spec review before final specification.

What specific Oxidizers/Disinfectants chemicals does this cover?

Named chemicals in this documentation: Hydrogen Peroxide (off-gassing), Sodium Hypochlorite (off-gassing).

What products are cited for Level Instrument in Oxidizers/Disinfectants service?

Documented examples include Icon MLR-70, GF Signet 2260/2291.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].