Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Chemical Compatibility

Storage Tank — Caustics/Bases

Strong evidence

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

Named chemicals

Sodium HydroxidePotassium Hydroxide

What LibertyCES's vendor documentation shows

Peabody's bulkhead-fitting table shows an unusual double-exclusion: both Viton and PVDF explicitly not recommended for NaOH, EPDM required.

Materials documented for this service

  • EPDM (required)
  • Viton (NOT recommended)
  • PVDF (NOT recommended)

Products cited for this service

Peabody ProChemPoly Processing IMFO/SAFE-Tank

Real Specifications

NaOH/KOH crystallization thresholdSensitive to temperatures below 65°F; insulation and heat tracing may be required at 50%+ concentrationpeabody-general-catalog.md
NaOH elastomer compatibilityEPDM compatible; Viton NOT recommended; PVDF NOT recommendedpeabody-general-catalog.md
NaOH tank warrantyXLPE construction carries a full, unconditional 5-year warranty for sodium hydroxide servicepoly-processing-chemical-storage.md
Install / Failure Note

Sodium hydroxide will crystallize and go solid if the tank isn't kept at the right temperature — Peabody ties this specifically to service below 65°F at 50%+ concentration, at which point insulation and heat tracing become a real design requirement, not an option.

Most suppliers default to Viton because it reads as the general "chemical-resistant" choice — but Peabody's own bulkhead-fitting table flags both Viton and PVDF as unsuitable for sodium hydroxide, with EPDM the material that actually holds. Liberty CES specs the elastomer against the chemical, not against a generic resistance label.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Is Storage Tank compatible with Caustics/Bases?

Peabody's bulkhead-fitting table shows an unusual double-exclusion: both Viton and PVDF explicitly not recommended for NaOH, EPDM required. This is strong evidence.

What materials are documented for Storage Tank in Caustics/Bases service?

Materials documented for this service: EPDM (required), Viton (NOT recommended), PVDF (NOT recommended). Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm with a spec review before final specification.

What specific Caustics/Bases chemicals does this cover?

Named chemicals in this documentation: Sodium Hydroxide, Potassium Hydroxide.

What products are cited for Storage Tank in Caustics/Bases service?

Documented examples include Peabody ProChem, Poly Processing IMFO/SAFE-Tank.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].