LibertyCES  ·  Graco Industrial Fluid Transfer  ·  Mining Pump Selection  ·  (559) 395-5500
Manufacturer Pillar · Industrial Fluid Transfer

Graco Industrial Pumps for Mining: SoloTech Peristaltic and QUANTM Electric Diaphragm

Graco Inc. manufactures multiple equipment lines. This LibertyCES page is scoped specifically to Graco's industrial fluid-transfer pumps for selected mining duties: SoloTech peristaltic hose pumps and QUANTM electric double diaphragm pumps.

Use this page to identify the primary mechanical fit before selecting an exact model, hose, diaphragm, wetted material, motor, voltage, or control configuration.
Page Scope

Graco's Industrial Fluid-Transfer Pump Line

Graco Inc. serves several markets, including contractor and homeowner spraying equipment as well as industrial manufacturing and fluid-handling systems. The products covered here are part of the industrial fluid-transfer side of Graco's business. This page does not cover caulk guns, paint sprayers, or other spraying equipment.

For mining and mineral-processing duties, LibertyCES focuses this manufacturer pillar on two distinct Graco pump families. SoloTech addresses selected low-flow dosing, abrasive slurry, and caustic transfer duties through a hose-isolated peristaltic design. QUANTM addresses selected AODD replacement, dewatering, transfer, and remote-control duties through an electrically driven double-diaphragm design.

Capability-Based Mining Fit

Mining use on this page is based on documented pump capabilities and application conditions. Exact suitability still depends on fluid chemistry, concentration, temperature, solids, viscosity, flow, pressure, duty cycle, and the selected configuration.

Two Different Primary Failure Modes

SoloTech removes dynamic process shaft seals and wetted check valves from the fluid path. QUANTM removes the compressed-air requirement while retaining diaphragm isolation and controllable electric operation.

Two Product Families

SoloTech and QUANTM Serve Different Primary Mining Duties

These pumps overlap in some transfer applications, but they should not be treated as interchangeable. Start with the duty's dominant failure mechanism and then verify the exact product configuration.

Graco SoloTech peristaltic hose pump for industrial reagent dosing and slurry transfer screening
Peristaltic · Hose-Isolated
Graco SoloTech

Primary Fit: Reagent Dosing and Abrasive Slurry Transfer

SoloTech uses a single roller to compress an engineered hose through a full rotation. The process fluid remains inside the hose, so the fluid path does not include a dynamic process shaft seal or wetted check valves. Graco describes the family for caustic, abrasive, or sensitive materials used in metering and transfer.

Key differentiator: the hose isolates the process fluid from the pump casing and removes two common wear or plugging points from abrasive and caustic service.

  • Precision reagent dosing where repeatable low-flow control is required
  • Abrasive lime slurry or selected solids-bearing chemical transfer
  • Caustic chemical metering when the hose and barb materials are compatible
  • Reversible line clearing when the process design permits reverse operation
View SoloTech Product Page
Graco QUANTM electric double diaphragm pump for industrial AODD replacement and dewatering screening
EODD · Electric Drive
Graco QUANTM

Primary Fit: AODD Replacement, Dewatering, and Remote Service

QUANTM is an electric double diaphragm pump designed to provide the operating behavior of a diaphragm pump without requiring compressed air. Graco states that qualifying installations can reduce energy usage and cost by up to 80% compared with pneumatic pumps. Integrated I/O supports remote operation and speed control.

Key differentiator: QUANTM replaces the compressed-air power train with an electric drive while preserving diaphragm isolation, stall-under-pressure behavior, and configurable process control.

  • Replacement of pneumatic AODD pumps where compressed-air cost or access is a problem
  • General dewatering and transfer within the selected model's pressure and solids limits
  • Remote-control or automated service using integrated I/O
  • Remote or solar-supported installations using a correctly engineered power and inverter package for the selected configuration
View QUANTM Product Page
Application Fit

Primary Fit, Not a Rigid Yes-or-No Matrix

Both product families can overlap in transfer and dispensing duties. The matrix below preserves the campaign's primary-fit logic while making the conditional areas explicit.

Screening rule: this table identifies the technology to investigate first. It does not approve a final pump model, chemical compatibility, solids passage, voltage, or operating point.

Application SoloTech QUANTM
Precision reagent dosing Primary fit Conditional
QUANTM can meter or dispense, but SoloTech is the low-flow precision default.
Abrasive slurry transfer Primary fit Model-dependent
Solids capacity varies by i30, i80, i120, and i120LP configuration.
AODD replacement Not typical Primary fit
General dewatering Limited / conditional Primary fit
Remote or solar-supported service Not manufacturer-promoted Documented capability
Selected systems may be supplied from 12/24 VDC sources through a correctly sized inverter and protection package.

Always confirm the exact pump model, fluid-section materials, hose or diaphragm materials, connection size, pressure limit, solids allowance, voltage, hazardous-location requirements, and control method before quotation.

Selection Process

How to Choose Between SoloTech and QUANTM

Start with the process duty rather than the brand name or maximum flow number.

STEP 01

Define the Actual Service

Record chemical, concentration, temperature, required flow and pressure, specific gravity, viscosity, solids size and concentration, suction conditions, and duty cycle.

STEP 02

Identify the Dominant Failure Mode

Use SoloTech as the primary review path when abrasive or caustic fluid is attacking seals or check valves and low-flow dosing matters. Use QUANTM when compressed air, AODD operating cost, dewatering, or remote control is the main problem.

STEP 03

Verify the Exact Configuration

Match the selected family to the real hydraulic point and complete wetted path. Manufacturer charts are screening tools; final approval requires current model data and project-specific compatibility review.

Send LibertyCES the real service conditions: chemical and concentration, temperature, flow, discharge pressure or head, suction conditions, viscosity, solids, duty cycle, available power, hazardous classification, desired controls, and current pump failure history.

Frequently Asked Questions

Graco Industrial Pumps for Mining FAQs

What is the difference between SoloTech and QUANTM for mining service?

SoloTech is a peristaltic hose pump whose primary fit is precision reagent dosing and selected abrasive slurry transfer because the fluid stays inside the hose and does not contact a dynamic process shaft seal or wetted check valves. QUANTM is an electric double diaphragm pump whose primary fit is AODD replacement, general dewatering, transfer, and remote-control service without compressed air.

Which Graco pump is the primary fit for precision reagent dosing?

SoloTech is the primary low-flow precision default in this campaign. QUANTM can meter or dispense in qualifying applications, but the required flow range, pulsation tolerance, pressure, fluid properties, and control accuracy must be checked before treating it as a dosing pump.

Can QUANTM replace an air-operated double diaphragm pump?

QUANTM is designed as an electric alternative to pneumatic diaphragm pumps and does not require compressed air. Graco states energy usage and cost reductions of up to 80% compared with pneumatic pumps in qualifying installations. The replacement still requires verification of the operating point, solids, fluid-section materials, voltage, hazardous-location rating, and controls.

Can QUANTM be used at remote or solar-supported mining sites?

Selected QUANTM configurations can support remote operation and can be integrated into engineered battery or solar-supported power systems through an appropriately sized inverter and electrical protection package. This is configuration-dependent and should not be treated as a universal direct-solar rating for every QUANTM model.

Before You Specify

Use the Mining Pump Selection Guide

Compare the two Graco pump families against the real application conditions before requesting pricing or replacing an existing pump.

Send the service data, not only the current pump model. LibertyCES will screen the duty against the selected SoloTech or QUANTM configuration.

Liberty Chemical Equipment & Supply Inc.
© 2026 Liberty Chemical Equipment & Supply Inc. · Graco Industrial Fluid-Transfer Pump Selection