Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Chemical Compatibility

Actuated Valve — Oxidizers/Disinfectants

Multi-source documented

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

Named chemicals

Chlorine GasChlorine DioxideSodium Hypochlorite
Direct answer

LibertyCES has documented Actuated Valve in Oxidizers/Disinfectants service, including Chlorine Gas, Chlorine Dioxide and Sodium Hypochlorite. Wetted materials to confirm: ALD70 diaphragm and Hastelloy. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

Netafim's ALD70 diaphragm chemical resistance chart gives hard fail ratings for chlorine gas, ClO2, and hypochlorite, requiring Hastelloy upgrade.

Materials documented for this service

  • ALD70 diaphragm (fails on Cl2/ClO2/NaOCl)
  • Hastelloy (upgrade)

Products cited for this service

Netafim 75/90/100 Series diaphragm-actuated valves

Real Specifications

SpecValueSource document
ALD70 diaphragm — Chlorine Gas & Chlorine DioxideBoth rated "Not Good" on Netafim's own ALD70 diaphragm chemical resistance chartNetafim Mining — Heap Leaching Products Catalog
ALD70 diaphragm — Sodium HypochloriteLimit 80°C @ 100 mg/L; Limit 30°C @ 170 mg/L — a concentration-and-temperature-dependent rating, not a flat passNetafim Mining — Heap Leaching Products Catalog
Hastelloy upgrade rationaleNetafim's own catalog states Hastelloy "is resistant against chlorine gas, hypochlorite and chlorine dioxide solutions" — the vendor-named substitute for all three chemistries where ALD70 failsNetafim Mining — Heap Leaching Products Catalog
Install / Failure Note

ALD70 rates a flat 'Not Good' for chlorine gas and chlorine dioxide regardless of concentration — an actuated diaphragm valve running either chemistry through a standard ALD70 diaphragm is a documented failure, not a marginal-service risk; Hastelloy is Netafim's own named substitute.

The valve body can be rated for a chemistry the diaphragm inside it flatly isn't — Netafim's own chart puts chlorine gas and chlorine dioxide at 'Not Good' for ALD70 even though the body/liner materials elsewhere in this family tolerate much harsher service. That's the kind of component-level gap a full application review catches and a body-spec-only quote misses.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can Actuated Valve handle Oxidizers/Disinfectants?

Netafim's ALD70 diaphragm chemical resistance chart gives hard fail ratings for chlorine gas, ClO2, and hypochlorite, requiring Hastelloy upgrade.

What wetted materials should Actuated Valve use in Oxidizers/Disinfectants service?

Materials documented for this service: ALD70 diaphragm (fails on Cl2/ClO2/NaOCl), Hastelloy (upgrade). Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Oxidizers/Disinfectants chemicals does this cover?

Named chemicals in this documentation: Chlorine Gas, Chlorine Dioxide, Sodium Hypochlorite.

Which Actuated Valve models are documented for Oxidizers/Disinfectants?

Documented examples include Netafim 75/90/100 Series diaphragm-actuated valves.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.

Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated