Chemical Compatibility

Drum Pump — Acids

Limited documentation

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

Named chemicals

Acids & bases (general, plating solutions)
Direct answer

LibertyCES has documented Drum Pump in Acids service, including Acids & bases. Wetted materials to confirm: Polypropylene, PVDF, 316SS and CPVC. Documented models include FTI Air Drum Pump Kit accessory. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

Drum pump kit accessory shares FTI Air AODD's acids & bases / plating applications; base drum-pump family only gives generic material list, no named chemical.

Materials documented for this service

  • Polypropylene
  • PVDF
  • 316SS
  • CPVC

Products cited for this service

Finish Thompson EF/PF/SF/TT/TB/HVDP/BT drum pumpsFTI Air Drum Pump Kit accessory

Real Specifications

SpecValueSource document
EF Series max temp by materialPP 150°F (66°C), PVDF 160°F (71°C), 316SS 212°F (100°C)Finish Thompson — Drum/Barrel Pumps
HVDP Series viscosity rangeHVDP-LR up to 100,000 cP; HVDP-HR up to 20,000 cPFinish Thompson — Drum/Barrel Pumps
Line-wide flammables warningShared across all 8 Finish Thompson drum/barrel series: pumping flammables or combustibles requires explosion-proof electric or air drive motors on stainless steel tubes with a static protection kitFinish Thompson — Drum/Barrel Pumps
FTI Air Drum Pump KitConverts a 1/2in FTI Air AODD pump into a drum pump; universal NPT/BSP/Buttress bung adapter, stainless steel hardwareFTI Air — Non-Metallic AODD Pumps
Install / Failure Note

Finish Thompson's own line-wide warning requires explosion-proof motors and a static-protection kit on stainless tubes for flammable/combustible drum service — skipping that kit on a solvent-adjacent acid drum job is a real ignition risk, not a formality.

EF Series' three wetted-material tiers span a 62°F range on temperature alone — PP tops out at 150°F, PVDF at 160°F, 316SS at 212°F — so an acid drum-pump quote isn't just "does the material resist the acid," it's whether the drum's actual draw-down temperature falls inside that specific material's rated window.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can Drum Pump handle Acids?

Drum pump kit accessory shares FTI Air AODD's acids & bases / plating applications; base drum-pump family only gives generic material list, no named chemical.

What wetted materials should Drum Pump use in Acids service?

Materials documented for this service: Polypropylene, PVDF, 316SS, CPVC. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Acids chemicals does this cover?

Named chemicals in this documentation: Acids & bases (general, plating solutions).

Which Drum Pump models are documented for Acids?

Documented examples include Finish Thompson EF/PF/SF/TT/TB/HVDP/BT drum pumps, FTI Air Drum Pump Kit accessory.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.

Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated