Named chemicals

Ferric Chloride (40%)Ammonium Sulfate (10%)
Direct answer

LibertyCES has documented Flow Meter in Salts/Brines service, including Ferric Chloride and Ammonium Sulfate. Wetted materials to confirm: PVDF/PEEK. Documented models include Blue-White MS6. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

Both salts included in MS6's factory-calibrated 7-chemical list.

Materials documented for this service

  • PVDF/PEEK

Products cited for this service

Blue-White MS6

Real Specifications

SpecValueSource document
MS6 factory-calibrated concentrationsFerric Chloride 40%, Ammonium Sulfate 10%Blue-White Industries — Flow Meters
MS6 flow range10-10,000 mL/min (0.158-158.5 GPH)Blue-White Industries — Flow Meters
MS6 max pressure200 psi (13.78 bar)Blue-White Industries — Flow Meters
MS6 fitting options½" barb, ½" M/NPT, ½" PVC slipBlue-White Industries — Flow Meters
Install / Failure Note

Ferric chloride and ammonium sulfate are both in MS6's 7-chemical factory list — a different salt or a higher concentration than 40%/10% falls outside the standard calibration and needs a factory custom-calibration request before ordering.

Ferric chloride is corrosive and stains on contact, which is exactly the kind of chemical where a flowmeter needs a specific factory-verified calibration rather than a generic 'PVDF is corrosion-resistant' assumption — Blue-White's own 7-chemical pre-calibration list is the actual evidence a spec should point to, not the body-material datasheet alone.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can Flow Meter handle Salts/Brines?

Both salts included in MS6's factory-calibrated 7-chemical list.

What wetted materials should Flow Meter use in Salts/Brines service?

Materials documented for this service: PVDF/PEEK. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Salts/Brines chemicals does this cover?

Named chemicals in this documentation: Ferric Chloride (40%), Ammonium Sulfate (10%).

Which Flow Meter models are documented for Salts/Brines?

Documented examples include Blue-White MS6.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.