Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Chemical Compatibility

pH/ORP Instrument — Salts/Brines

Manufacturer-documented

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

Named chemicals

Cyanide (CN-)Hexavalent Chromium (Cr6+)
Direct answer

LibertyCES has documented pH/ORP Instrument in Salts/Brines service, including Cyanide and Hexavalent Chromium. Wetted materials to confirm: Open-ring diaphragm. Documented models include ProMinent PHED/PHEX/RHEX. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

PHED explicitly named for electroplating media contaminated with Cr6+ and CN-.

Materials documented for this service

  • Open-ring diaphragm (PHEX/RHEX)

Products cited for this service

ProMinent PHED/PHEX/RHEX

Real Specifications

SpecValueSource document
ProMinent PHED applicationProcess water/electroplating contaminated with Cr6+, CN-ProMinent — Measuring, Control and Sensor Technology
PHED max temperature/pressure80°C / 8 barProMinent — Measuring, Control and Sensor Technology
PHED diaphragm2x ceramic, double junctionProMinent — Measuring, Control and Sensor Technology
PHEX/RHEX max temperature/pressure25°C/16bar or 100°C/6barProMinent — Measuring, Control and Sensor Technology
PHEX diaphragm designOpen ring diaphragm (high-solids, no chemical contamination service)ProMinent — Measuring, Control and Sensor Technology
Electroplating rinse water contaminated with cyanide or hexavalent chromium needs a double-junction sensor, not a standard single-junction pH probe — ProMinent's PHED is built specifically with a 2x ceramic double-junction diaphragm for this contaminated-media service, rated to 80°C/8 bar, distinct from the plain PHEP/PHES sensors quoted for clean drinking or process water.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can pH/ORP Instrument handle Salts/Brines?

PHED explicitly named for electroplating media contaminated with Cr6+ and CN-.

What wetted materials should pH/ORP Instrument use in Salts/Brines service?

Materials documented for this service: Open-ring diaphragm (PHEX/RHEX). Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Salts/Brines chemicals does this cover?

Named chemicals in this documentation: Cyanide (CN-), Hexavalent Chromium (Cr6+).

Which pH/ORP Instrument models are documented for Salts/Brines?

Documented examples include ProMinent PHED/PHEX/RHEX.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.

Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated