Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Guides / Pumps & Controls

SCADA-Ready Monitoring & Automation

Guaranteeing Compliance and Uptime

Remote tank level, leak detection, gas safety, and telemetry — engineered for one source of truth. We specify sensors, RTUs, and communications that integrate cleanly with your HMI/SCADA so alarms are trusted and audits are defensible.

Direct answer: SCADA-ready monitoring and automation unifies remote tank level, leak detection, gas safety, and telemetry into a single source of truth so alarms are trusted and audits are defensible. That means specifying the right sensor technology per application (80-GHz radar for vapor/foam-tolerant level, ultrasonic for open basins, guided wave radar for tall tanks, discrete switches for overfill), consistent 4-20 mA/HART/Modbus signal standards, and cellular RTUs with SCADA protocol mapping — plus correctly specified deadbands, alarm priority, and latching standards, since a mis-specified sensor threshold is the most common cause of nuisance alarm trips.

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →
80-GHz
Radar Level Tech
4-20 mA
Modbus / DNP3
Cellular
ORION / BEACON RTUs
NEMA 4X/7
Enclosure Ratings
The James Factor

Doing It Yourself vs. Specifying With James Riggins

FactorDoing It YourselfWith James Riggins
Tag Mapping & Scaling12–24 hrs3–6 hrs (60–75% saved)
Alarm Nuisance RateHighLow via standards & deadbands
Comms Loss BehaviorUndefinedFail-safe defined
Docs for AuditPartialComplete (P&IDs, I/O, ranges)
Product Lineup

Monitoring System Capabilities

Level Technologies

80-GHz radar for vapor/foam-tolerant continuous level · Ultrasonic for open basins & clear airspace · Guided wave radar for tall/complex tanks · Discrete switches for overfill & secondary alarms

Signal & Power Standards

4-20 mA w/ HART, pulse, and Modbus options · 24 VDC control, surge protection, clean grounding · Cal/scale routines and naming conventions (LIT-###)

RTUs & Endpoints

Cellular RTUs (Telog class) for remote lift stations · ORION/BEACON cellular endpoints for meters · SCADA protocols: Modbus, DNP3; mapped tag sets · Edge alarming to reduce network chatter

Proactive Safety — Leak & H₂S Detection

Floor/well sensors and containment basins with alarm I/O · Fixed H₂S monitors at lift stations with alarm relays & periodic bump-test · Acoustic leak detection loggers for non-revenue water loss

FAQ

Frequently Asked Questions

What is the goal of SCADA-ready monitoring and automation?

One source of truth — unifying remote tank level, leak detection, gas safety, and telemetry into a single SCADA/HMI system so alarms are trusted and audits are defensible.

How does acoustic leak detection work in distribution networks?

Acoustic loggers detect the sound signature of leaks across distribution networks, supporting non-revenue water loss detection without excavation.

What reduces alarm nuisance rates in a monitoring system?

Correctly specified deadbands, alarm priority, and latching/acknowledgement standards — a mis-specified sensor with the wrong threshold is the most common cause of nuisance trips.

Spec Review

Get this spec'd right the first time

Send LibertyCES your process conditions — James matches technology, materials, and controls to your exact application.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Related

Related Guides & Products

Sensing & Control Products →Level And Flow Controls →