Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Industries / Chemical & Plating

Chemical & Plating Solutions

Chrome reduction and cyanide destruction pH/ORP control, high-purity plating bath tank material, and plating-line filtration with precious metal recovery — for metal-finishing and electroplating operations.

Three Problem Types in Chemical & Plating

Match the Setpoint and Material to the Chemistry, Not the Catalog

Problem Type 01

Chrome Reduction & Cyanide Destruction pH/ORP Control

Hexavalent chromium reduction runs at pH 2.0–2.5 with an ORP setpoint near -300mV; cyanide destruction runs at pH 11.5 with ORP at +450mV in its first stage — real, vendor-published pretreatment setpoints for metal-finishing and electroplating wastewater, with the gas-release hazards most specs miss.

Chrome Reduction & Cyanide Destruction — pH/ORP Setpoints →
Problem Type 02

Plating Bath Tank Material Selection

Natural polypropylene with zero pigments and zero fibers is specified for nickel sulfamate and other high-purity plating baths — eliminating the leachables that would otherwise contaminate the plating chemistry.

Houston PolyTank Expansion Tanks for Plating Chemistry →
Problem Type 03

Plating Line Filtration & Precious Metal Recovery

MF acid/alkaline filter systems handle precious metal plating, high chloride, sulfuric, and alkaline cyanide solutions — plus an MR-SR Metal Recovery Chamber that recovers up to 3 troy oz of precious metal per pound of ion exchange resin from rinse and drag-out tanks.

Filter Pump — Plating Filtration & Metal Recovery →
FAQ

Frequently Asked Questions

What are the real setpoints for chrome reduction and cyanide destruction on a plating line?

Hexavalent chromium reduction is controlled at pH 2.0–2.5 with an ORP setpoint near -300mV (-400mV max) and a minimum 15-minute detention time, using sulfur dioxide, sodium sulfite, or sodium metabisulfite as the reducing agent. Cyanide destruction runs its first stage at pH 11.5 with ORP held at +450mV to convert cyanide to cyanate, then a second neutralization stage. Both processes carry a real gas-release hazard if setpoints are pushed past what the process needs.

What tank material is used for nickel sulfamate and other high-purity plating baths?

Natural polypropylene with zero pigments and zero fibers — this eliminates the leachables that would otherwise contaminate high-purity plating chemistry, and supports the tight lead times (typically 4-6 weeks) that plating facility buildouts and commissioning schedules require.

Can precious metals be recovered from plating rinse water?

Yes — an MR-SR Metal Recovery Chamber using ion exchange resin recovers up to 3 troy oz of precious metal per pound of resin from rinse water and drag-out tanks, while also improving rinse-water purity for reuse.

What information does LibertyCES need to spec chemical/plating equipment?

The specific plating chemistry (chrome, cyanide, nickel sulfamate, or other bath type), concentration, flow rate, temperature, and whether the application is pretreatment (reduction/destruction), storage/containment, or filtration/recovery — process data first, part number second.

Specifying equipment for a plating line?

Send LibertyCES the bath chemistry, flow, and whether you need pretreatment, tank/containment, or filtration — we'll confirm the setpoints and material before you spec a model.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].