XOMOX Tufline Low Emission HF4D Sleeved Plug Valve

A dedicated plug valve for hydrofluoric acid alkylation and derivatives service, built around leak detection and zero packing adjustments.

Direct answer

The XOMOX Low Emission HF4D is a soft-seated sleeved plug valve for hydrofluoric acid alkylation service, 1/2 to 12 inches, Class 300, -20°F to 500°F. Crane CPE describes it as the first soft-seated sleeved plug valve meeting ISO 15848-1 and API 641 with zero packing adjustments during thermal cycling, with a fourth sealing barrier and optional HF detection paint.

Specifications

HF4D at a glance

Manufacturer-published values. Confirm size, class and materials for your order with a spec review.
Valve typeSoft-seated sleeved plug valve (Tufline/Tuflin family)
Size1/2 in to 12 in
Pressure classClass 300
Temperature-20°F to 500°F
Body materialsM35-1 alloy, carbon steel
Emissions standardsISO 15848-1 and API 641, with zero packing adjustments during thermal cycling
SealingFourth sealing barrier (4D stem packing)
Leak detectionHF detection paint option
Named serviceHF alkylation and HF derivatives

Source: Crane ChemPharma & Energy — XOMOX Tufline/Tuflin Sleeved Plug Valves

Why the extra barrier and the detection paint

Hydrofluoric acid alkylation units cycle temperature regularly, and a plug valve that needs repacking on every cycle is both a maintenance burden and a safety liability. The HF4D's fourth sealing barrier and its HF detection paint option exist because an undetected HF leak is a serious safety event. They are leak-detection features specific to HF alkylation service, not generic accessories.

How the HF4D compares with the other Tufline low-emission valves

Sleeved plug valve variants in the same Crane CPE catalog.
ModelSizeClassTemperatureStandards and service
Low Emission HF4D1/2–12 inClass 300-20 to 500°FISO 15848-1 and API 641; HF alkylation and derivatives
Tertiary Top Seal (hydrofluoric)1/2–12 inClass 300/600 DR-20 to 600°FEPA Method 21 and API 607; listed by UOP and ConocoPhillips for HF alkylation units
3D (Low Emission)1/2–16 inClass 150/300, PN63-20 to 600°FISO 15848-1
SR (Severe Service)1/2–12 inClass 150/300-20 to 500°FAPI 641; names sulfuric acid alkylation, zero packing adjustments across 3 thermal cycles
XP31/2–12 inClass 150/300-20 to 392°FISO 15848-1; chlorine, caustic soda, vinyl chloride, TDI/MDI, ethylene oxide
SSV (Severe Service)1/2–16 inClass 150/300/600-20 to 600°FEPA Method 21
FE01/2–16 inPN10–40, Class 150/300-148 to 572°FCertified below 20 ppm (AH class), triple sealing system

Source: Crane ChemPharma & Energy — XOMOX Tufline/Tuflin Sleeved Plug Valves

Ordering

Tell James the service (HF alkylation, HF derivatives or another toxic-gas duty), the size and class, and the operator you need (bare stem, gear or actuator). We confirm availability and options with the manufacturer before you order.

FAQ

Frequently Asked Questions

What is the XOMOX Low Emission HF4D plug valve?

It is a soft-seated sleeved plug valve from Crane CPE (XOMOX) for HF alkylation and HF derivatives service, in 1/2 to 12 inch sizes, Class 300, rated -20°F to 500°F. Crane CPE describes it as the first soft-seated sleeved plug valve to meet both ISO 15848-1 and API 641 with zero packing adjustments during thermal cycling.

What does the HF4D fourth sealing barrier and HF detection paint do?

The fourth barrier is a 4D stem packing, and the optional HF detection paint shows a leak. Both exist because an undetected hydrofluoric acid leak is a serious safety event, so they are leak-detection and containment features specific to HF service.

What is the difference between the HF4D and the Tertiary Top Seal?

Both are dedicated HF-service plug valves in 1/2 to 12 inch sizes. The HF4D is Class 300 to 500°F. The Tertiary Top Seal is Class 300 and 600 DR to 600°F, is EPA Method 21 and API 607 certified, and its design is listed by UOP and ConocoPhillips for HF alkylation units.

Which XOMOX plug valve is for sulfuric acid alkylation?

Crane CPE names the SR (Severe Service) valve for sulfuric acid alkylation. It meets API 641 with zero packing adjustments across three thermal cycles. The HF4D is the valve it names for HF alkylation.