Richter Chemie-Technik
Sealless magnetic-drive centrifugal pumps and PTFE/PFA-lined valves for aggressive chemical service — German-engineered, ENVIPACK maintenance-free stem sealing.
Richter Chemie-Technik makes sealless magnetic-drive centrifugal pumps (MNK, MPB, QMD, RM) and PTFE/PFA-lined valves for aggressive chemical service. MNK and RM use an eddy-current-free CFRP/PTFE containment can; MPB self-primes and handles up to 30% gas content. Ball valves use ENVIPACK maintenance-free stem sealing, and the NK butterfly valve reaches DN1000 (40 inch).
What LibertyCES specifies from Richter Chemie-Technik

Eddy-current-free CFRP/PTFE containment can and rare-earth SmCo/NdFeB magnets — MPB tolerates up to 30% gas content, RM requires no O-rings.

ENVIPACK maintenance-free self-adjusting stem seal standard across the entire ball valve range, DIN EN ISO 15848-1 + SIL certified.

NK reaches DN1000 (40") — the widest size range of any Richter valve — with triple stem sealing and PFA disc + PTFE body lining.
Richter Chemie-Technik — Real Catalog Spec Data
| Product Line | Model | Category | Material | Size / Capacity | Temp Rating |
|---|---|---|---|---|---|
| Centrifugal Magnetic Drive Pumps | MNK - Heavy Duty | Pump | PFA/PTFE/PFA-conductive lining, EN-JS1049/ASTM A395 housing, CFRP/PTFE double can, SmCo/NdFeB magnets | 25-25-100 to 200-150-315 | PN16, -60C to 200C |
| Centrifugal Magnetic Drive Pumps | MPB - Peripheral Magnetic Drive Pumps | Pump | PFA lining, EN-JS1049/ASTM A395 housing, SSiC bearings | 25-25-115 | PN16, -60C to 150C, self-priming, handles up to 30% gas content |
| Centrifugal Magnetic Drive Pumps | QMD - Standard Duty | Pump | FEP lining, EN-JS1049/ASTM A395 housing | 40-25-160 to 80-50-200 | PN16, -10C to 100C |
| Centrifugal Magnetic Drive Pumps | RM - Medium Duty | Pump | PFA lining, EN-JS1049/ASTM A395 housing, CFRP/PTFE double can, SmCo/NdFeB magnets, no O-rings | 40-25-125 to 80-50-200 | PN16, -30C to 150C |
| Centrifugal Mechanically Sealed Pumps | SCK/F | Pump | PFA/PTFE/PFA conductive lining, EN-JS 1049/ASTM A395 housing | 25-25-100 to 150-125-315 | -60C to +180C (-80F to +360F) |
| Centrifugal Mechanically Sealed Pumps | SCK-S/F (Self-Priming) | Pump | PFA/PTFE/PFA conductive lining, EN-JS 1049/ASTM A395 housing | 50-32-160 | -60C to +180C (-80F to +360F) |
| Centrifugal Mechanically Sealed Pumps | SCK-X/F (Vortex) | Pump | PFA/PTFE/PFA conductive lining, EN-JS 1049/ASTM A395 housing | 25-25-160 to 125-100-200 | -60C to +180C (-80F to +360F) |
| Ball Valves | BVA | Valve | PFA lining, EN-JS 1049 housing | 1"-6" / DN25-DN150, Class 150 | -60C to +200C |
| Ball Valves | KA-N | Valve | PFA lining, ENVIPACK stuffing box, EN-JS 1049 housing | 2"/1"-6"/4" or DN50/25-DN150/100, 16 bar | -60C to +200C |
| Ball Valves | KK | Valve | PFA lining, sandwich/flangeless design, EN-JS 1049 housing | DN25-DN150, 16 bar | -60C to +200C |
| Ball Valves | KN/KNA | Valve | PFA lining, ENVIPACK stuffing box, EN-JS 1049 housing | ISO DN15-DN200, ASME 0.5"-8", 16 bar | -60C to +200C |
| Ball Valves | KNR | Valve | PFA lining, ENVIPACK stuffing box, EN-JS 1049 housing | ISO DN15-DN200, ASME 0.5"-8", 16 bar | -60C to +200C |
| Ball Valves | TE | Valve | PFA lining, EN-JS 1049 housing, ball or Al2O3 ceramic ball | DN80, 10 bar | -40C to +180C (-40F to +360F) |
| Butterfly Valves | NK | Valve | PFA disc + PTFE body lining, triple stem sealing, EN-JS 1049 housing | 2"-40" / DN50-DN1000, 10 bar | -40C to +200C |
| Butterfly Valves | NKS-T | Valve | PFA disc + PTFE body lining, EN-JS 1049 housing | DN80, 10 bar | -40C to +180C |
Sourced from Richter Chemie-Technik's own catalog documentation.
Frequently Asked Questions
What makes Richter magnetic drive pumps energy-efficient?
The MNK and RM families use an eddy-current-free CFRP/PTFE composite containment can instead of the standard metal can most mag-drive pumps use, avoiding the wasted energy and heat that eddy-current losses generate as the drive magnet rotates.
Which Richter pump handles gas-laden liquids?
The MPB Peripheral Magnetic Drive Pump safely pumps liquids with up to 30% gas content and is self-priming without an additional suction tank — a real, distinct capability the other three centrifugal families are not designed for.
Is there a Richter valve rated specifically for chlorine service?
The RSS bellows-sealed control valve carries an explicit "Chlor application: special design for particularly long service life" claim, with thick-walled PFA lining for maximum permeation resistance.
Does Richter serve semiconductor and high-purity applications?
Yes — Richter's own spec table lists a dedicated Semi-Conductor/Photovoltaic sector for high-purity and ultra-high-purity water, pure chemicals, and acids. See LibertyCES's semiconductor & high-purity manufacturing page for the full manufacturer cluster.
Get the right magnetic drive pump or lined valve for your chemistry
Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].
Richter Chemie-Technik models in the LibertyCES catalog
30 models across 9 product lines. For most models that state them (the middle 80%): connection sizes 0.5–8 in; pressure to 232 psi (16.0 bar); temperature to 86°F (30°C). Extremes are in the table.
| Model / line | Type | Size / capacity / flow | Pressure | Temperature | Wetted material | Source |
|---|---|---|---|---|---|---|
| Centrifugal Magnetic Drive Pumps MNK - Heavy Duty | Pump | 25-25-100 to 200-150-315 | 61–140 °F (16–60 °C) | PFA/PTFE/PFA-conductive lining, EN-JS1049/ASTM A395 housing, CFRP/PTFE double can, SmCo/NdFeB magnets | Richter Chemie-Technik — Industries + Centrifugal Magnetic Drive Pumps | |
| Centrifugal Magnetic Drive Pumps MPB - Peripheral Magnetic Drive Pumps | Pump | 25-25-115 | 61–140 °F (16–60 °C) | PFA lining, EN-JS1049/ASTM A395 housing, SSiC bearings | Richter Chemie-Technik — Industries + Centrifugal Magnetic Drive Pumps | |
| Centrifugal Magnetic Drive Pumps QMD - Standard Duty | Pump | 40-25-160 to 80-50-200 | 50–61 °F (10–16 °C) | FEP lining, EN-JS1049/ASTM A395 housing | Richter Chemie-Technik — Industries + Centrifugal Magnetic Drive Pumps | |
| Centrifugal Magnetic Drive Pumps RM - Medium Duty | Pump | 40-25-125 to 80-50-200 | 61–86 °F (16–30 °C) | PFA lining, EN-JS1049/ASTM A395 housing, CFRP/PTFE double can, SmCo/NdFeB magnets, no O-rings | Richter Chemie-Technik — Industries + Centrifugal Magnetic Drive Pumps | |
| Centrifugal Mechanically Sealed Pumps SCK/F | Pump | 25-25-100 to 150-125-315 | -60C to +180C (-80F to +360F) | PFA/PTFE/PFA conductive lining, EN-JS 1049/ASTM A395 housing | Manufacturer documentation on file | |
| Centrifugal Mechanically Sealed Pumps SCK-S/F (Self-Priming) | Pump | 50-32-160 | -60C to +180C (-80F to +360F) | PFA/PTFE/PFA conductive lining, EN-JS 1049/ASTM A395 housing | Manufacturer documentation on file | |
| Centrifugal Mechanically Sealed Pumps SCK-X/F (Vortex) | Pump | 25-25-160 to 125-100-200 | -60C to +180C (-80F to +360F) | PFA/PTFE/PFA conductive lining, EN-JS 1049/ASTM A395 housing | Manufacturer documentation on file | |
| Ball Valves BVA | Valve | 1"-6" / DN25-DN150, Class 150 | to -76 °F (to -60 °C) | PFA lining, EN-JS 1049 housing | Richter Chemie-Technik — Ball Valves | |
| Ball Valves KA-N | Valve | 2"/1"-6"/4" or DN50/25-DN150/100, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, ENVIPACK stuffing box, EN-JS 1049 housing | Richter Chemie-Technik — Ball Valves |
| Ball Valves KK | Valve | DN25-DN150, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, sandwich/flangeless design, EN-JS 1049 housing | Richter Chemie-Technik — Ball Valves |
| Ball Valves KN/KNA | Valve | ISO DN15-DN200, ASME 0.5"-8", 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, ENVIPACK stuffing box, EN-JS 1049 housing | Richter Chemie-Technik — Ball Valves |
| Ball Valves KNR | Valve | ISO DN15-DN200, ASME 0.5"-8", 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, ENVIPACK stuffing box, EN-JS 1049 housing | Richter Chemie-Technik — Ball Valves |
| Ball Valves TE | Valve | DN80, 10 bar | 145 psi (10 bar) | -40C to +180C (-40F to +360F) | PFA lining, EN-JS 1049 housing, ball or Al2O3 ceramic ball | Richter Chemie-Technik — Ball Valves |
| Butterfly Valves NK | Valve | 2"-40" / DN50-DN1000, 10 bar | 145 psi (10 bar) | to -40 °F (to -40 °C) | PFA disc + PTFE body lining, triple stem sealing, EN-JS 1049 housing | Richter Chemie-Technik — Butterfly Valves |
| Butterfly Valves NKS-T | Valve | DN80, 10 bar | 145 psi (10 bar) | to -40 °F (to -40 °C) | PFA disc + PTFE body lining, EN-JS 1049 housing | Richter Chemie-Technik — Butterfly Valves |
| Check Valves BC/CV (Ball Check Valve) | Valve | ASME 0.5"-6", ISO DN15-DN100, Class 150/16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining (4-5mm), EN-JS1049/ASTM A395 housing | Richter Chemie-Technik — Check Valves |
| Check Valves GR (Stem Check Valve) | Valve | 0.5"-4" / DN15-DN100, Class 150 | to -76 °F (to -60 °C) | PFA lining (5-6mm), EN-JS 1049 housing | Richter Chemie-Technik — Check Valves | |
| Check Valves RV (High Capacity Check Valve) | Valve | DN150, DN200, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PTFE lining, EN-JS 1049 housing | Richter Chemie-Technik — Check Valves |
| Check Valves SR (Sight Glass Check Valve) | Valve | DN25-DN150, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, borosilicate glass sight glass, EN-JS 1049 housing | Richter Chemie-Technik — Check Valves |
| Control Valves HV (Bellows-Sealed) | Valve | 1"-4" / DN15-DN100, 16 bar/Class 150 | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, PTFE or Hastelloy C bellows, EN-JS 1049 housing | Manufacturer documentation on file |
| Control Valves RSS (Bellows-Sealed Control Valve) | Valve | 0.5"-6" / DN15-DN150, 16 bar | 232 psi (16 bar) | -60C to +180C (-75F to +356F) | Thick-walled PFA lining, PTFE bellows, EN-JS 1049 housing | Manufacturer documentation on file |
| Safety and Overflow Valves GU/GUT (Overflow Valve) | Valve | GU 1"-3"/DN25-DN80; GUT 1"/DN25, 16 bar/Class 150 | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, bellows design (hermetically tight), EN-JS 1049 housing | Manufacturer documentation on file |
| Safety and Overflow Valves KSE 3.0 (Safety Valve) | Valve | DN25/50-DN100/150, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining (incl. blow-off area), cast steel 1.0619+N (GP240GH) housing | Manufacturer documentation on file |
| Safety and Overflow Valves LPV (Aerating/Deaerating Valve) | Valve | DN50/80-DN100/150, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA/PTFE lining, weight-loaded | Manufacturer documentation on file |
| Sight Glasses PSG | Sight Glass | DN25-DN150, 16 bar | 232 psi (16 bar) | -60C to +180C (-75F to +360F) | PFA lining, borosilicate glass panes, EN-JS 1049 housing | Richter Chemie-Technik — Sight Glasses |
| Sight Glasses SGS | Sight Glass | DN15-DN100, 6 bar | 87 psi (6 bar) | -60C to +150C (-75F to +300F) | PFA lining, borosilicate glass panes, cylindrical, EN-JS 1049 housing | Richter Chemie-Technik — Sight Glasses |
| Sight Glasses TSG | Sight Glass | DN25-DN80, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining, borosilicate glass panes, EN-JS 1049 housing | Richter Chemie-Technik — Sight Glasses |
| Sliding Stem Valves BAV (Bottom Drain Stem Valve) | Valve | DN80/50, DN100/80, DN150/100, 10 bar | 145 psi (10 bar) | -60C to +180C (-75F to +360F) | Thick-walled PTFE lining, vacuum-proof, EN-JS 1049 housing | Richter Chemie-Technik — Sliding Stem Valves |
| Sliding Stem Valves MV (Diaphragm Valve) | Valve | 1"-6" / DN15-DN200, 16/10/7 bar (size dependent) | 102 psi (7 bar) | to -22 °F (to -30 °C) | PFA lining, TFM-PTFE diaphragm with EPDM support | Richter Chemie-Technik — Sliding Stem Valves |
| Sliding Stem Valves PA (Sampling Valve) | Valve | DN25-DN80, 16 bar | 232 psi (16 bar) | to -76 °F (to -60 °C) | PFA lining or stainless steel bottle, EN-JS1049/1.4435 housing | Richter Chemie-Technik — Sliding Stem Valves |