Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Sector Application

Benchtop Meter-Mix-Dispense System (PR70) for Electronics Manufacturing

Strong evidence

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

What LibertyCES's vendor documentation shows

Graco's PR70 key-market list names automotive components/electronics first. Family specs: ratio to 24:1 by model, shot size 2.0-70cc, ratio accuracy ±1%; epoxies, sealants, adhesives, silicones, urethanes. This is the benchtop tier — the right answer for low-volume electronics potting where a GSD cell is oversized. Manuals 312761EN-E, 312760EN, 312759EN, 338863EN-D.

Products cited in this application

Graco PR70e (1:1-12:1 fixed, built-in purge timer, includes Local Control Module)PR70 (1:1-12:1 fixed, multiple tube sizes/UI levels)PR70v (1:1-24:1 variable, up to 70cc)PRO70f (fixed 1:1-12:1 / variable 1:1-24:1, advanced flow control, up to 15 PLC flow selections)PR70s (servo control, unlimited PLC flow selections)

Real Specifications

Family shot size range2.0cc to 70ccgraco-sealants-adhesives.md
Ratio accuracy±1%graco-sealants-adhesives.md
PR70v ratio range1:1 to 24:1 (variable)graco-sealants-adhesives.md
PR70s automationServo motor control, unlimited PLC flow selectionsgraco-sealants-adhesives.md
Rated materialsEpoxies, sealants, adhesives, silicones, urethanesgraco-sealants-adhesives.md
Install / Failure Note

PR70 covers 2.0-70cc shots at ±1% accuracy; per Graco's own cross-product comparison table, work needing more than 70cc per shot or a hydraulic drive escalates to HFR, which carries a 30cc minimum shot on that platform.

Electronics assembly at bench scale doesn't need a full automated GSD cell — it needs repeatable ±1% shots in the 2-70cc range. Automotive components/electronics heads Graco's own PR70 key-market list, and picking PR70e vs. PR70s isn't cosmetic: PR70s's unlimited PLC flow selections is what an automated changeover line needs, where PR70e's fixed purge timer is the manual-bench answer.

Every claim on this page traces to real, vendor-published documentation on file with LibertyCES. Confirm current specifications with the manufacturer before final specification.

FAQ

Is Benchtop Meter-Mix-Dispense System (PR70) used in Electronics Manufacturing?

Graco's PR70 key-market list names automotive components/electronics first. Family specs: ratio to 24:1 by model, shot size 2.0-70cc, ratio accuracy ±1%; epoxies, sealants, adhesives, silicones, urethanes. This is the benchtop tier — the right answer for low-volume electronics potting where a GSD cell is oversized. Manuals 312761EN-E, 312760EN, 312759EN, 338863EN-D. This is strong evidence.

What products are specified for Benchtop Meter-Mix-Dispense System (PR70) in Electronics Manufacturing?

Documented examples include Graco PR70e (1:1-12:1 fixed, built-in purge timer, includes Local Control Module), PR70 (1:1-12:1 fixed, multiple tube sizes/UI levels), PR70v (1:1-24:1 variable, up to 70cc), PRO70f (fixed 1:1-12:1 / variable 1:1-24:1, advanced flow control, up to 15 PLC flow selections), PR70s (servo control, unlimited PLC flow selections) — confirm current specifications with the manufacturer before final selection.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].