Drum Pump for Plating
30+ years spec experience. Send James the process data and get a real answer — not a catalog page.
Request a Spec Review →Yes. LibertyCES has documented Drum Pump in Plating applications, including Finish Thompson AC/GP Series. The right model depends on the fluid, concentration, temperature, flow and duty cycle, so send James your process data for a free spec review before final selection.
Notes from the vendor documentation
Plating listed among finish Thompson sealed/drum pump family applications.
Products cited in this application
Real Specifications
| Spec | Value | Source document |
|---|---|---|
| AC Series max temp | Max temperature 300°F (149°C) — the highest of any Finish Thompson series in this dataset | Finish Thompson — Sealed Pumps |
| AC Series flow/head | Max head 263 ft (80.2 m), max flow 321 gpm (73.0 m³/h) [AC8] | Finish Thompson — Sealed Pumps |
| GP Series suction pressure by seal type | Bellows seal max suction pressure 15 psi (1 bar); multi-spring seal 65 psi (4.5 bar) | Finish Thompson — Sealed Pumps |
| GP Series construction | Molded housings of chemical-resistant polypropylene or PVDF; effectively handles caustics, acids, plating solutions | Finish Thompson — Sealed Pumps |
GP Series' suction pressure envelope depends entirely on which seal type is fitted — bellows seal tops out at 15 psi while multi-spring reaches 65 psi; specifying the wrong seal type for the actual inlet pressure is a real, documented mis-spec risk within the same GP model line.
The exact same GP Series pump body handles plating solutions at either 15 psi or 65 psi max suction depending purely on seal type — a spec sheet that just says 'GP22' without naming the seal isn't a complete spec.
Every claim on this page traces to real, vendor-published documentation on file with LibertyCES. Confirm current specifications with the manufacturer before final specification.
Related Guides
FAQ
How is Drum Pump used in Plating?
Plating listed among finish Thompson sealed/drum pump family applications.
Which Drum Pump models are specified for Plating?
Documented models include Finish Thompson AC/GP Series. Confirm current specifications with the manufacturer before final selection.
What does LibertyCES need to size Drum Pump for a Plating application?
The fluid and its concentration, operating temperature, flow or volume, pressure and suction conditions, duty cycle, and the existing equipment it replaces or connects to. James reviews it for free.
Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].
Send James your spec
Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.
Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated