Skip to main content
LibertyCES — Engineering Line Direct: Call James Riggins at (559) 395-5500 — 30+ Years Spec Experience. No sales queue. Real engineering answers.
Type to search 990+ pagesBrowse everything →
Chemical Compatibility

Metering/Dispensing System — Caustics/Bases

Multi-source documented

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →

Named chemicals

Sodium Hydroxide
Direct answer

LibertyCES has documented Metering/Dispensing System in Caustics/Bases service, including Sodium Hydroxide. Wetted materials to confirm: PVC/PP dosing skid. Documented models include GF Signet precision dosing systems. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a free spec review.

Notes from the vendor documentation

Cyanide destruction batch process explicitly doses NaOH via precision dosing pump/system to reach pH 11.5 setpoint.

Materials documented for this service

  • PVC/PP dosing skid

Products cited for this service

GF Signet precision dosing systems (cyanide destruction NaOH+chlorine)

Real Specifications

SpecValueSource document
Cyanide destruction Stage 1 pH setpointpH 11.5, held via small NaOH adjustmentsGF Piping Systems — Application Solutions Made Easy: Chemical Process Industry
Stage 1 ORP oxidation targetORP raised to +450mV via chlorine additionGF Piping Systems — Application Solutions Made Easy: Chemical Process Industry
Two-Step process oxidation targetOxidation to below 0.1 ppm (cyanide → cyanate)GF Piping Systems — Application Solutions Made Easy: Chemical Process Industry
Two-Step Stage 2 detention timeUp to 4-hour detention time in modern systems, pH lowered with sulfuric acidGF Piping Systems — Application Solutions Made Easy: Chemical Process Industry
Post-neutralization bath monitoring target9.5 pH, 450 mV oxidation level maintainedGF Piping Systems — Application Solutions Made Easy: Chemical Process Industry
Install / Failure Note

GF Signet's own process documentation warns that acid injection must be manually locked out during Stage 1 of batch cyanide destruction — letting pH drop below 11 risks releasing toxic cyanogen chloride gas and stops the cyanide-to-cyanate oxidation from completing properly.

A NaOH dosing skid quoted for cyanide destruction isn't just about hitting a pH number — GF Signet ties the pH 11.5 setpoint directly to a gas-release safety threshold, which means the acid-injection interlock logic matters as much as the pump's turndown ratio.

Every material and product claim on this page traces to real, vendor-published documentation on file with LibertyCES. Chemical compatibility depends on exact concentration, temperature, and duty cycle — confirm current specifications with the manufacturer and request a spec review before final specification.

FAQ

Can Metering/Dispensing System handle Caustics/Bases?

Cyanide destruction batch process explicitly doses NaOH via precision dosing pump/system to reach pH 11.5 setpoint.

What wetted materials should Metering/Dispensing System use in Caustics/Bases service?

Materials documented for this service: PVC/PP dosing skid. Compatibility depends on exact concentration, temperature and duty cycle, so confirm with a spec review before final specification.

Which Caustics/Bases chemicals does this cover?

Named chemicals in this documentation: Sodium Hydroxide.

Which Metering/Dispensing System models are documented for Caustics/Bases?

Documented examples include GF Signet precision dosing systems (cyanide destruction NaOH+chlorine).

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.

Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated