Level Instrument
LibertyCES has documented Level Instrument in 4 industries, including Municipal Water, Municipal Wastewater and Chemical Processing. Chemical compatibility is documented for Acids and Oxidizers/Disinfectants. Documented models include SmartCover SmartLevel Sewer, Flowline LD32 and Icon MLR-70 guided wave radar. Send James the fluid, concentration, temperature and flow for a free spec review.
30+ years spec experience. Send James the process data and get a real answer — not a catalog page.
Request a Spec Review →Where LibertyCES specs Level Instrument
Municipal Water
Multi-source documentedWater Distribution explicitly listed application.
Municipal Wastewater
Multi-source documentedSewer/manhole and wastewater lift station explicitly named applications.
Chemical Processing
Multi-source documentedLiquid Chemical Storage and Chemical Sumps explicitly named applications.
Plating
Manufacturer-documentedChemical Sumps application overlaps with plating bath/rinse tank service.
Chemical compatibility
Acids
Manufacturer-documentedLD33 explicitly named for 'Corrosive chemical' service; MLR-70 named for Liquid Chemical Storage and Chemical Sumps.
Oxidizers/Disinfectants
Manufacturer-documentedRadar/guided-wave technology explicitly noted as not affected by vapor/outgassing relevant to H2O2/NaOCl off-gassing.
Level Instrument: models in the LibertyCES catalog
34 models across 13 product lines from 4 manufacturers. For most models that state them (the middle 80%): temperature to 302°F (150°C). Extremes are in the table.
| Model / line | Manufacturer | Type | Size / capacity / flow | Pressure | Temperature | Wetted material | Source |
|---|---|---|---|---|---|---|---|
| Level Sensors HLS Series | Hayward Flow Control | Instrument | 0-15 and 0-33 ft range | 0–140 °F (-18–60 °C) | CPVC housing with Al2O3 sensing diaphragm | Hayward Flow Control — Mining Guide | |
| Indicating Level Transmitters HLST Series | Hayward Flow Control | Instrument | - | 100-240 VAC 50-60Hz | NEMA 4X (IP65) face | Hayward Flow Control — Mining Guide | |
| Level Transmitters LR80/81/83/85 (80 GHz Radar) | Flowline | Instrument | 32.8-393.7 ft range | 140–248 °F (60–120 °C) | PVDF/PFA antenna | Flowline — Level Products | |
| Level Transmitters UG/US Series (Reflective Ultrasonic) | Flowline | Instrument | 9.8-39.3 ft range | to 176 °F (to 80 °C) | PVDF transducer | Flowline — Level Products | |
| Level Transmitters DX10/DL Series (Ultrasonic) | Flowline | Instrument | 1.25-5.5 m range | to 140 °F (to 60 °C) | PVDF | Flowline — Level Products | |
| Level Transmitters LD30-LD37 (Pressure/Submersible) | Flowline | Instrument | up to 34.65 ft range | 316 stainless, PVC, PUR, PTFE, or FEP | Flowline — Level Products | ||
| Level Transmitters LR15/16/20/21 (26 GHz Radar) | Flowline | Instrument | 65.6-98.4 ft range | to 302 °F (to 150 °C) | 316L, optional PTFE | Flowline — Level Products | |
| Level Transmitters LR36/41 (26 GHz Radar, Solids) | Flowline | Instrument | 49.2-229.7 ft range | 392–752 °F (200–400 °C) | 316L, optional PTFE dust shield | Flowline — Level Products | |
| Level Transmitters LG10 (Guided Wave) | Flowline | Instrument | 9.8 ft range | to 302 °F (to 150 °C) | 316L probe | Flowline — Level Products | |
| Tank Level Monitors HB01 | Flowline | Instrument | 1-4 BLE sensor inputs | IP67 enclosure | Flowline — Level Products | ||
| Level Switches AXXX/AX23/AX1X/AX13 (Corrosion Resistant) | Flowline | Instrument | top/wall mount | -40–176 °F (-40–80 °C) | PP or PP/PVDF | Flowline — Level Products | |
| Level Switches LU10 (Ultrasonic Switch) | Flowline | Instrument | universal mount | -40–176 °F (-40–80 °C) | PP/PFA | Flowline — Level Products | |
| Level Switches LZ12 (Vibration Switch) | Flowline | Instrument | universal mount | -40–176 °F (-40–80 °C) | PP-Ryton | Flowline — Level Products | |
| Level Switches LP15 (Capacitance Switch) | Flowline | Instrument | universal mount | -40–176 °F (-40–80 °C) | PP | Flowline — Level Products | |
| Level Switches LV10 (Buoyancy Switch) | Flowline | Instrument | top mount | -40–176 °F (-40–80 °C) | PP/PVDF | Flowline — Level Products | |
| Level Switches LO10 (Optic Leak Switch) | Flowline | Instrument | universal mount | -40–176 °F (-40–80 °C) | PP/PFA | Flowline — Level Products | |
| Level Controllers & Indicators LI55/LC52/LI23/LI24 (for Transmitters) | Flowline | Instrument | - | panel/rail mount enclosure | Flowline — Level Products | ||
| Level Controllers & Indicators LC40-42/LC10/LC11/LC0X (for Switches) | Flowline | Instrument | - | panel/rail mount enclosure | Flowline — Level Products | ||
| Level Monitoring (SmartCover) SmartLevel Sewer Level Monitoring System | Badger Meter | Instrument | manhole-mounted or subsurface | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) SmartLevel Surface Level Monitoring System | Badger Meter | Instrument | surface/pole mount | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) H2Scents Hydrogen Sulfide Level Sensor | Badger Meter | Instrument | - | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) SubSonic Dual Pressure & Ultrasonic Level Sensor | Badger Meter | Instrument | manhole-mounted | sealed/submersible | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) Ultrasonic Level Sensor | Badger Meter | Instrument | manhole-mounted | sealed/splashproof | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) UnderCover Intrusion Monitoring System | Badger Meter | Instrument | manhole or vault lid | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) EchoSmart Sludge Blanket Monitor | Badger Meter | Instrument | - | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) FilterSmart Backwash Monitor | Badger Meter | Instrument | - | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | ||
| Level Monitoring (SmartCover) Beluga Submersible Area Velocity Flow Meter | Badger Meter | Instrument | open channel | -4–122 °F (-20–50 °C) | - | Badger Meter — Level Monitoring (SmartCover ecosystem) | |
| Level Monitoring (SmartCover) Raven-Eye 2 Non-Contact Radar Flow Meter | Badger Meter | Instrument | open channel | -4–122 °F (-20–50 °C) | non-wetted (non-contact radar) | Badger Meter — Level Monitoring (SmartCover ecosystem) | |
| Submersible Liquid Level Sensors 100/200C/300S/TankPro/LP 100 | Icon Process Controls | Instrument | - | PVC/PP/PVDF/316SS/PTFE housing, Kalrez or FKM seals, Ceramic Al2O3 or 316SS diaphragm | Icon Process Controls — Level Sensors, Sentinel Remote Monitoring, Level Displays | ||
| Radar Liquid Level Sensors ProScan 3/ProScan 2/ProScan/MLR-70 | Icon Process Controls | Instrument | 10-20m range | CPVC/316SS/GFPP enclosure, PP/PTFE/316SS antenna, aluminum alloy (MLR-70) | Icon Process Controls — Level Sensors, Sentinel Remote Monitoring, Level Displays | ||
| Ultrasonic Liquid Level Sensors UltraPro 2000/ViewSonic | Icon Process Controls | Instrument | 3-10m range | PTFE Teflon (UltraPro) or PP (ViewSonic) | Icon Process Controls — Level Sensors, Sentinel Remote Monitoring, Level Displays | ||
| CFL Float Liquid Level Sensor CFL Series | Icon Process Controls | Instrument | up to 6 ft tank height | PVC/PP/PVDF/316SS | Icon Process Controls — Level Sensors, Sentinel Remote Monitoring, Level Displays | ||
| Liquid Level Switches PLF/PLA/AlertPro/TFS/LP25/PLS/NC15/NC25/NC30/FloatPro | Icon Process Controls | Instrument | 6"-72" (PLF) | PVC/PP/PVDF/316SS (PLF) | Icon Process Controls — Level Sensors, Sentinel Remote Monitoring, Level Displays | ||
| Liquid Level Displays ShoPro/TVL/TVU/ITC 450/ITC 450B/ITC 350/250B/250L | Icon Process Controls | Instrument | - | -40–158 °F (-40–70 °C) | polycarbonate (wall) or NORYL (panel) | Icon Process Controls — Level Sensors, Sentinel Remote Monitoring, Level Displays |
This table is part of the equipment catalog dataset (CSV and JSON).
Technical guides for Level Instrument
Frequently Asked Questions
What industries use Level Instrument?
LibertyCES has documented Level Instrument specified across 4 sector applications, including Municipal Water, Municipal Wastewater, Chemical Processing and Plating.
How is Level Instrument used in Municipal Water?
Water Distribution explicitly listed application. — examples include GF Signet 2260 Ultrasonic Level Transmitter. This is well-documented in LibertyCES's field data.
Can Level Instrument handle Acids?
LD33 explicitly named for 'Corrosive chemical' service; MLR-70 named for Liquid Chemical Storage and Chemical Sumps. Materials to confirm: PTFE, FEP, PVDF, 316SS. Specific chemicals include Corrosive chemical service (general).
Which chemicals can Level Instrument handle?
LibertyCES has documented chemical compatibility records for Level Instrument across 2 chemical families, including Acids, Oxidizers/Disinfectants.
Send LibertyCES the process data, not a part number
Fluid, chemistry, concentration, temperature, flow, pressure, line size, and current equipment — that's what a real spec review needs to start.
Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].
Other sensing & control categories
Send James your spec
Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.
Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated