Direct answer

LibertyCES has documented pH / ORP Electrode in Aquatics / Aquariums / Water Parks / Zoos / Swimming Pools. Chemical compatibility is documented for Metal Plating & Photographic Process Solutions. Documented models include ProMinent DULCOTEST PHES, PHEK and RHES Pt and RHES Au. Send James the fluid, concentration, temperature and flow for a free spec review.

30+ years spec experience. Send James the process data and get a real answer — not a catalog page.

Request a Spec Review →
1 sector application

Where LibertyCES specs pH / ORP Electrode

Aquatics / Aquariums / Water Parks / Zoos / Swimming Pools

Multi-source documented
ProMinent DULCOTEST PHES (drinking/pool water, 1-12 pH, 60°C/3 bar, 1x ceramic) · PHEK (pool + aquariums, plastic shaft) · RHES Pt and RHES Au · RHEK Pt (pool + aquariums, plastic shaft) · RHEKL Pt (2x ceramic, horizontal install)

ProMinent names pool water and aquariums as the typical application for five distinct sensor types; the plastic-shaft PHEK/RHEK variants exist specifically for aquatic installs. Real detail: RHES Au uses gold electrodes because gold resists the hydrogen susceptibility that degrades platinum in pool water.

1 chemical compatibility record

Chemical compatibility

Metal Plating & Photographic Process Solutions

Multi-source documented
hexavalent chromium (Cr6+)cyanide (CN-)sulfide (S2-)mercury (Hg2+)copper (Cu+/Cu2+)lead (Pb2+)perchlorate (ClO4-)bromide (Br-)iodide (I-)silver sulfide (Ag2S)silver bromide (AgBr)silver iodide (AgI)silver cyanide (AgCN)hydrofluoric acid <2%fluoride etching solutions
Materials: Ryton (PPS) electrode body · PTFE reference junction (2734-2736) vs UHMWPE (2724-2726) vs differential isolated chamber (2764-2767) · HDPE diaphragm (ProMinent PHEF, fluoride service) · HF-resistant glass variants (2724-HF/2726-HF/2734-HF/2736-HF) · Signet rating scale: Ø Not Recommended, ** Compatible, *** Good, ***** Better
GF Signet 2764-2767 Harsh Chemicals differential pH/ORP electrodes (differential 3-electrode design with a refillable, rebuildable reference chamber; Ag/AgCl element in a glass-encased housing separated from a KCl/KNO3-buffered chamber, physically isolating it from poisoning ions) · GF Signet 2774-2777 hybrid (KNO3/KCl polyacrylamide gel reference, PTFE double reference junction, targets Cu2+/Pb2+/Hg2+ only) · GF Signet 2734-2736 High Performance (PTFE reference junction, 10-100°C) · GF Signet 2724-2726 General Purpose (UHMWPE reference junction) and 2724-HF/2726-HF for HF <2% · GF Signet 2759 pH/ORP System Tester (simulates pH 4/7/10 and ORP ±700mV without buffer solutions) · GF Signet 2760 preamplifier / 2750-7 DryLoc pH electronics · ProMinent PHED (process water and electroplating, chemically contaminated e.g. Cr6+ and CN-, 2x ceramic double junction, 1-12 pH, 80°C/8 bar) · ProMinent PHEF (low-pH fluoride media, e.g. etching solutions in electroplating, 1x HDPE diaphragm, 0-12 pH, 50°C/7 bar)

Models

pH / ORP Electrode: models in the LibertyCES catalog

5 models across 1 product line from 1 manufacturer.

Manufacturer-stated values from the documents cited in the last column. A blank cell means the document doesn’t state it. Confirm exact options with a spec review.
Model / lineManufacturerTypeSize / capacity / flowPressureTemperatureWetted materialSource
pH/ORP Electrodes
2724-2726 General Purpose pH/ORP
Georg Fischer (GF Signet)InstrumentationpH 0-14, ORP +-2000mV99 psi (6.8 bar)14–185 °F (-10–85 °C)Ryton (PPS) body, glass, UHMWPE junction, FKMGF Signet — Instrumentation Product Range Brochure
pH/ORP Electrodes
2734-2736 High Performance pH/ORP
Georg Fischer (GF Signet)InstrumentationpH 0-14, ORP +-2000mV100 psi (6.9 bar)50–212 °F (10–100 °C)Ryton (PPS) body, glass, PTFE junction, FKMGF Signet — Instrumentation Product Range Brochure
pH/ORP Electrodes
2764-2767 Harsh Chemicals Differential pH/ORP
Georg Fischer (GF Signet)InstrumentationpH 0-14, ORP +-2000mVresists Hg/Cu/Pb/CN/S2-/silver-complex poisoningRyton (PPS) body, glass, differential Ag/AgCl reference chamberGF Signet — Instrumentation Product Range Brochure
pH/ORP Electrodes
2774-2777 Hybrid pH/ORP
Georg Fischer (GF Signet)InstrumentationpH 0-14, ORP +-2000mVresists Cu2+/Pb2+/Hg2+ poisoningRyton (PPS) body, PTFE double reference junctionGF Signet — Instrumentation Product Range Brochure
pH/ORP Electrodes
2760 Preamplifier DryLoc Sensor Electronics
Georg Fischer (GF Signet)InstrumentationpH 0-14, ORP +-2000mV32–185 °F (0–85 °C)Valox (PBT) in-line, CPVC submersibleGF Signet — Instrumentation Product Range Brochure

This table is part of the equipment catalog dataset (CSV and JSON).

FAQ

Frequently Asked Questions

What industries use pH / ORP Electrode?

LibertyCES has documented pH / ORP Electrode specified across 1 sector application, including Aquatics / Aquariums / Water Parks / Zoos / Swimming Pools.

How is pH / ORP Electrode used in Aquatics / Aquariums / Water Parks / Zoos / Swimming Pools?

ProMinent names pool water and aquariums as the typical application for five distinct sensor types; the plastic-shaft PHEK/RHEK variants exist specifically for aquatic installs. Real detail: RHES Au uses gold electrodes because gold resists the hydrogen susceptibility that degrades platinum in pool water. — examples include ProMinent DULCOTEST PHES (drinking/pool water, 1-12 pH, 60°C/3 bar, 1x ceramic), PHEK (pool + aquariums, plastic shaft), RHES Pt and RHES Au, RHEK Pt (pool + aquariums, plastic shaft), RHEKL Pt (2x ceramic, horizontal install). This is well-documented in LibertyCES's field data.

Can pH / ORP Electrode handle Metal Plating & Photographic Process Solutions?

pH / ORP Electrode has documented compatibility with Metal Plating & Photographic Process Solutions Materials to confirm: Ryton (PPS) electrode body, PTFE reference junction (2734-2736) vs UHMWPE (2724-2726) vs differential isolated chamber (2764-2767), HDPE diaphragm (ProMinent PHEF, fluoride service), HF-resistant glass variants (2724-HF/2726-HF/2734-HF/2736-HF), Signet rating scale: Ø Not Recommended, ** Compatible, *** Good, ***** Better. Specific chemicals include hexavalent chromium (Cr6+), cyanide (CN-), sulfide (S2-), mercury (Hg2+), copper (Cu+/Cu2+), lead (Pb2+), perchlorate (ClO4-), bromide (Br-), iodide (I-), silver sulfide (Ag2S), silver bromide (AgBr), silver iodide (AgI), silver cyanide (AgCN), hydrofluoric acid <2%, fluoride etching solutions.

Spec Review

Send LibertyCES the process data, not a part number

Fluid, chemistry, concentration, temperature, flow, pressure, line size, and current equipment — that's what a real spec review needs to start.

Ready to buy or need a fast answer? Call, text, or email James directly — (559) 395-5500 · [email protected].

Sensing & Control

Other sensing & control categories

Chlorine / Chlorine Dioxide Analyzer PanelChrome Reduction / Cyanide Destruction Control SystemClamp-On Ultrasonic Flow MeterConductivity / Resistivity ElectrodeControllerController / Process AnalyzerFlow MeterHydrostatic Level SensorLevel InstrumentMagmeter / Paddlewheel / Turbine Flow MeterOptical Dissolved Oxygen SensorPool / Aquatic Facility ControllerPressure / Leak Monitoring RTUPressure InstrumentRadar / Ultrasonic / Hydrostatic Level TransmitterRadar Level TransmitterSCADA / Remote Monitoring IntegrationSanitary Conductivity / Resistivity ElectrodeSight GlassTemperature SensorToxic / Combustible Gas DetectorWater MeterpH/ORP Instrument
Free spec review

Send James your spec

Fluid, concentration, temperature, flow or volume, and where it goes. James replies with a real answer, not a catalog page.

Reviewed by James Riggins, 30+ years specifying water and chemical process equipment · Updated