Precision Level & Flow Controls: 80-GHz Radar, Ultrasonic & Pump Protection

Radar, ultrasonic, pressure, guided-wave, flow meters, switches, and multi-parameter controllers—engineered, specced, and supplied by Liberty to eliminate overflows, protect pumps, automate chemical feed, and give you real-time SCADA visibility.

80-GHz Radar
Reflective Ultrasonic
Pressure/Submersible
Guided-Wave Radar
4–20 mA / HART / Modbus
SCADA-Ready
Spec-Driven By James Riggins
Compliance NEMA 4X / IP67
Procurement Speed Submittals streamlined
0
80-GHz Radar Range (m, liquid)
0.04 fps
Low-Flow Trip (thermal)
0
Wireless Battery Life (years)
4–20 mA
Analog + Digital Protocols

The James Factor: Specifying Level & Flow Right the First Time

With 30+ years in water, wastewater, and chemical processing, James Riggins matches technology, geometry, and outputs to your exact process—preventing false echoes, dry-run, and overflow incidents before they happen.

Factor
Doing It Yourself
With James Riggins
Tech selection (radar/ultrasonic/pressure/GWR)
8–16 hrs research
2–4 hrs matched to media/geometry (60–80% saved)
Mounting & echo handling
Trial-and-error
Verified nozzle length, dead-band, false-echo map
Pump interlocks & dry-run protection
Reactive trips
Proactive thermal switch + trip logic
SCADA scaling & comms
Rework & rescaling
First-pass 4–20 mA / HART / Modbus mapping
Total impact
Max uptime, clean trends, zero-leak compliance

Level & Flow Control Lineup

From high-range 80-GHz radar to reflective ultrasonic and low-flow pump protection—everything you need for accurate measurement and safe automation.

Flowline EchoBeam LR85 80-GHz radar level sensor for liquids and solids
80-GHz Radar — EchoBeam LR80/81/83/85
  • Range: up to 120 m (liquid), 60 m (solids)
  • Outputs: 4–20 mA / HART / Modbus
  • Materials: PVDF / PFA antenna
  • Setup: LevelTap™ App
Flowline EchoPod reflective ultrasonic level transmitter for condensing applications
Reflective Ultrasonic — EchoPod / EchoTouch
  • Range: to 12 m
  • Resists: condensation
  • Outputs: 4–20 mA + relays
  • Mount: 2" NPT
Flowline LD Series submersible/external pressure level transmitter
Pressure Level — LD Series
  • Enclosures: NEMA 6P / 4X
  • Range: to 10.6 m
  • Materials: 316SS / PTFE / FEP
  • Use: lift stations & corrosives
Flowline Thermo-Flo FT10 thermal flow switch for pump protection
Thermal Low-Flow Switch — FT10
  • Trip: 0.04–3 fps (adjustable)
  • Wetted: PP / PVDF
  • Enclosure: NEMA 4X
  • Role: pump dry-run protection

Specification Snapshot

Category Model / Series Range / Size Outputs Materials Notes
Radar (Liquid/Solid)Flowline EchoBeam LR80/81/83/8510–120 m4–20 mA / HART / ModbusPVDF / PFALevelTap™ App; NPT or 3" flange
Ultrasonic (Liquid)EchoPod UG / EchoTouch US3–12 m4–20 mA (+ relays)PVDFReflective face resists condensation
Pressure LevelFlowline LD30–LD37to 10.6 m4–20 mA316SS / PTFE / FEPNEMA 6P submersible
Guided-Wave RadarFlowline LG10 / ICON GWRto 3 m (rod/coax)4–20 mA316L / FEPFoam, vapor, turbulence tolerant
Flow — Insertion MagHayward HEX8001"–12", 0.28–20 fps4–20 mA + displayPVC, Hastelloy CBuilt-in rate/total; 24 VDC
Flow — PaddlewheelBlue-White F-1000/F-2000⅜"–12", up to 8000 GPMBattery / 4–20 mA / alarmsVariesNEMA 4X; batching options
Flow — Thermal SwitchFlowline FT100.04–3 fpsSPST relayPP / PVDFPump dry-run protection
Controller / IndicatorFlowline LI/LCRelays + 4–20 mANEMA 4X faceplatePanel/rail; display + alarms
Multi-Param ControllerHayward HMC200/HMC3001–8 channelsAnalog, relaysNEMA 4XWeb-enabled (HMC300)
DisplaysICON TVF / TVF-450Relays + 4–20 mAPC enclosureBright LED, wall/panel
Wireless GatewayFlowline LevelHub HB011–4 sensorsLTE-M + BLEIP67 PBTUp to 8-yr battery; sub $195/yr

Applications & Industries

Deployed across water, wastewater, and industrial chemical processes.

Water & Wastewater Treatment
Chemical Day Tanks & Sumps
Clarifiers & Lift Stations
RO/IX Skids & Filtration
Rail Car & Tanker Unloading
Pulp & Paper / Mining
Fume Scrubbers
SCADA/PLC Integration
Food & Beverage CIP (check materials)

Why This Stack Works

Clean Signals
Correct tech + geometry removes false echoes & drift.
Interlock Safety
Thermal low-flow trips prevent dry-run & cavitation.
SCADA-Ready
Scaled 4–20 mA with HART/Modbus for fast commissioning.

Spec it right the first time.

Get a free, one-on-one consult with James Riggins to match the right instruments and wiring to your process.

Talk to James    Request a Spec

Frequently Asked Questions

Which level technology should I choose for chemicals with foam or vapor?

Use 80-GHz radar or guided-wave radar. Both handle foam/vapor; guided-wave excels in tight tanks/turbulence.

How do I protect pumps from dry-run?

Add the Flowline FT10 thermal flow switch interlocked to your pump control—trip at a safe low-flow setpoint.

Can I see all tanks on my phone?

Yes. Pair EchoBeam radar sensors with the LevelHub HB01 LTE-M gateway and the LevelTap™ App for dashboards and alerts.

Do these tie into SCADA/PLC?

All systems support industrial outputs: 4–20 mA, relays, and protocol options like HART/Modbus depending on model.